Everstar Air Conditioner Error Codes
Everstar Air Conditioner Error Codes

Everstar Air Conditioner Error Codes

Everstar Air Conditioner Error Codes The first step in troubleshooting is always to clearly define the problem. What are you expecting to happen, and what is happening instead? Answering those questions can often point you toward the answer.

We’ve split our troubleshooting steps into two sections: basic troubleshooting for major problems that keep a portable air conditioner from working at all, and performance troubleshooting for air conditioners that don’t cool as well as you need them to.

Everstar Air Conditioner Error Code Solutions

Error CodesProblem-Solution
P1The LCD window will shows “P1” and the Water Full indicator will flash every 0.5 seconds.
P2Compressor does not work and the digital display area shows “ P2 “. The bottom tray is full
E1The cooting indicator light flashes at 1H: and the digital display area shows “E1 “. The room temperature Sensor is off or shon-circuit.
E2The FAN indicator light flashes at 1H: and the digital display area shows “ E2 “. The Evaporator Temperature Sensor is off or short-circuit.
E3The Dehumidifying indicator light flashes at 1H: and the digital display area shows ”E3”. The Condenser Temperature Sensor is off or short-circuit.

Troubleshooting

Troubles: Unit does not Start when Pressing onloff Button

Possible Causes:

  1. Wateriull indicator blinks, water tank is full.
  2. Room temperature is higher than the set temperature.
  3. Room temperature is lower than the set temperature.

Suggest Remedies:

  1. Dump the water in the water tank.
  2. Reset the temperature.
  3. Reset the temperature.

Troubles: Not cool enough

Possible Causes:

  1. The windows or doors in the room are not closed.
  2. There are heat sources inside the room.
  3. Exhaust air duct is not connected or blocked.
  4. Temperature setting is too high.
  5. Air filter is blocked by dust.

Suggest Remedies:

  1. Make sure all the windows and doors are closed.
  2. Remove the heat sources it possible.
  3. Connect the duct and make sure it can function properly.
  4. Decrease the set temperature.
  5. Clean the air filter.

Troubles: Noisy or vibration

Possible Causes: The ground is not level or not flat enough.

Suggest Remedies: Place the unit on a flat. level ground if possible.

Troubles: Gurgling sound

Possible Causes: The sound comes from the flowing of the refrigerant inside the air conditioner.

Suggest Remedies: It is normal.

How to Fix P1 Error?

How to Fix P1 Error

This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows “P1” and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied. Condensed water will be accumulated in the water tank.

When the tank is full, the LED window will show “P1” and the Water Full indicator light start flashing. At this time the air cooling process will immediately stop. However, the fan motor will continue to operate (this is normal). Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to it’s original position (in cabinet) and the air cooling process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.