Galanz Air Conditioner Error Codes

Galanz Air Conditioner Error Codes When the outdoor coil pipe TEMP sensor is out of order or removed, the air conditioner will set to defrost automatically in order to prevent it not working normally while the outdoor coil pipe TEMP sensor  is malfunction.

Galanz Air Conditioner Error Code Solutions

Fault F6: PG motor faults

Fault F7: Indoor TEMP sensor faults

Fault F8: Indoor coil pipe TEMP sensor faults

Fault F9: Outdoor coil pipe TEMP sensor faults

Galanz Air Conditioner Error Codes

Wall Mounted Type

Indoor unit display and solve methods of protector stop ingredients in indoor unit and outdoor unit

Error CodesTrouble
F1Heat overloading protector
F2Cool freeze protector
F3Instantaneous power cut
F4direct current fan motor no feedback
1Fcool overloading protector
2Fexhaust overheating protector
3Fover or not enough pressure protector
4Fover-current protector
5FIPM protector
6Fdefrost state
7Fdirect current compressor drive exceptional
8Fdirect current compressor cannt start

Trouble Solve Methods

E1: The trouble of indoor unit room temperature sensor.

E2: The trouble of unit pipe temperature sensor. indoor

E3: The trouble of PG motor

E5: The trouble of bad communication of indoor unit and outdoor unit.

E6: The EEPRO of indoor unit error

1E: The trouble of outdoor unit pipe temperature sensor

3E: The trouble of exhaust sensor

4E: The EEPRO of indoor unit error

8E: The trouble of PFC.

Galanz Air Conditioner Display Meaning

Troubleshooting

The following cases are not troubles that will obstruct you in using please follow the fault analysis and continue using.

Operation of air conditionerExplanation
Fan speed setting is not allowed in AUTO or DRY modeThe speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode
Compressor stops operation intermittently in DRY modeCompressor operation is automatically controlled in DRY mode depending on the room temperature and humidity
Compressor of the outdoor unit is operating although it is turned off in HEAT modeWhen the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed
Timer indicator lamp lights up and the air conditioner does not operateTimer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled
The compressor and indoor fan stop intermittently in HEAT modeThe compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode
Indoor fan and outdoor fan stop intermittently in HEAT modeThe compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation
The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreasesThe compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature