Senville Air Conditioner Error Codes

Senville Air Conditioner Error Codes Running into technical issues is a common problem that can be resolved. While it may seem like an impossible issue at the time, these codes often mean something more. Below is a sheet we’ve created in relation to So Good To Buy products that describe different issues your unit might be going though. While contacting technical support is highly recommended, giving a technician a brief understanding of a potential issue can really help them out and get the problem resolved ASAP.

Senville Air Conditioner Error Code Solutions

Indoor Unit Error Display:

Error CodesLED Status
E0EEPROM parameter error
E1Indoor / outdoor units communication protection
E2Zero-crossing signal error
E3Indoor fan speed out of control
E5Open or short circuit of outdoor temperature sensor or outdoor unit EEPROM parameter error
E6Open or short circuit of room or evaporator temperature sensor
E7Outdoor fan speed out of control
P0IBM malfunction or IGBT over-strong current protection
P1Over voltage or too low voltage protection
P2Temperature protection of compressor top.
P4Inverter compressor drive error

Outdoor unit error display:

On the outdoor PCB, there are two LED lights. One is green, the other is red. You can judge what the error is through the status of the two lights.

Indoor Unit Display: P1

LED 6 (Green) Light,  LED 5 (RED) Light: Over voltage or too lows or too voltage protection

Indoor Unit Display: P2

LED 6 (Green) Light,  LED 5 (RED) Flash: Over voltage or too lows or too voltage protection

Indoor Unit Display: P4

LED 6 (Green) Off,  LED 5 (RED) Flash: Inverter compressor drive error

Indoor Unit Display: P4

LED 6 (Green) Flash,  LED 5 (RED) Light: Inverter compressor drive error

Indoor Unit Display: P4

LED 6 (Green) Flash,  LED 5 (RED) Flash: Inverter compressor drive error

Indoor Unit Display: P0

LED 6 (Green) Flash,  LED 5 (RED) Off: IBM malfuntion or IGBT over-strong current protection

Indoor Unit Display: Stand by

LED 6 (Green) Light,  LED 5 (RED) Off: Stand by

Outdoor unit error display

Troubleshooting

Malfunctions: Unit does not start

Cause:

  1. Power cut
  2. Unit may have become Unplugged
  3. Fuse may have blown
  4. Battery in Remote controller may have been exhausted
  5. The time you have set with timer is incorrect

What should be done:

  1. Wait for power to be restored
  2. Check that plug is securely in wall receptacle
  3. Replace the fuse
  4. Replace the battery
  5. Wait or cancel timer setting

Malfunctions: Unit not cooling or heating (Cooling/ heating models only) room very well while air flowing out from the air cond tioner

Cause:

  1. Inappropriate temperature setting
  2. Air filter is blocked
  3. Doors or Windows are open
  4. Air inlet or outlet of indoor or outdoor unit has been blocked
  5. Compressor 3 minutes protection has been activated

What should be done:

  1. Set temperature correctly. For detailed method please refer to ”Using remote control” section
  2. Clean the air filter
  3. Close the doors or windows
  4. Clear obstructions away first, then restart the unit
  5. Wait

Malfunctions: The unit starts and stops frequently

Cause:

  1. There’s too much or too little refrigerant in the system
  2. Incompressible gas or moisture has entered the system.
  3. The compressor is broken
  4. The voltage is too high or too low

What should be done:

  1. Check for leaks and recharge the system with refrigerant.
  2. Evacuate and recharge the system with refrigerant
  3. Replace the compressor
  4. Install a manostat to regulate the voltage

Issue: Both the indoor unit and outdoor unit make noises

Possible Causes:

  1. Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
  2. Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
  3. Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.

OPERATION indication lamp: This lamp illuminates when the air conditioner is in operation.

AUTO indication lamp: Lights up during the Auto operation.

Ion indication lamp (optional function)Lights up when Clean Air feature is activated and Ionizer can generate abundant anions to fill the room with refreshing and natural air.

TIMER indication lamp: Lights up during Timer operation.

DEFROST indication lamp (For cooling & heating models only): Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.

DIGITAL DISPLAY: Displays the current setting temperature and malfunction/protection code when the air conditioner is in operation.

Frequency display: This display is separated into five zones. The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones.