Vestel Air Conditioner Error Codes Error Messages are displayed, respectively by first the Er icon and then the special code (01, 02, …, 20, etc.) of the failure. In that case, do nothing to the air conditioner and contact with the Authorised Service. Er11 and Er13 are not error messages. If you see these messages, apply the steps under the following protection messages section.
Vestel Air Conditioner Error Code Solutions
Error Codes | Cause |
---|---|
dF | The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled. |
RE | Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service. |
Sr | In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the failure. In that case, you don’t need to turn your air conditioner off. It is needed to contact with the authorized service immediately |
HL | There is a fluctuation in the electrical voltage, wait for its recovery. |
ER11-13 | The codes of ER-13 and ER-11, and the messages displayed on the indoor unit display, are protection messages in the aim of preventing the product from some harmful consequences resulting from an excessiv current coming from the compressor. The product turns off right after it enters into these protections. In the case that it is re-operated by the remote control, cooling and heating functions restart. |
Vestel STV 42 Fault codes in living room air conditioners
E1 | High temperature in the discharge line |
E2 | Compressor draws excessive current |
E3 | There is a phase error (phase sequence) |
E5 | Low pressure protection (Bridge socket 301 on outdoor unit) |
E6 | Indoor unit frost protection |
E2 | Compressor leads wrong phase missing |
E6 | Indoor unit evap dirty low usage temperature environment may be extremely cold. |
Vestel s28 and s45 series air conditioner fault codes
E1 | Room sensor open circuit |
E2 | Room sensor short circuit |
E5 | Defrost sensor open circuit |
E6 | Defrost sensor short circuit |
Vestel LCD display air conditioner fault codes
88 | Power outage protection (waits for a while) |
E2 | indoor unit sensor |
E3 | Indoor pipe sensor |
E4 | Indoor unit fan failure |
E5 | Gas leak |
E6 | voltage low/high |
E7 | Electronic card memory erased |
Vestel FS 42 series air conditioner indoor unit fault codes
ff01 | Indoor unit ice protection |
ff02 | Outdoor unit error in cooling |
ff03 | High temperature protection in cooling |
ff04 | High temperature protection in heating |
ff05 | Outdoor unit error in heating |
ff06 | High pressure protection |
ff07 | room sensor |
ff08 | Indoor unit pipe sensor |
ff09 | Outdoor unit pipe sensor |
Fault codes according to the flashing of the LEDs on the outdoor unit card
LED 5+1 | wrong phase |
LED 5+4+1 | missing phase |
LED 3+1 | High pressure protection |
LED 5+3+1 | Low pressure protection |
LED 4+3+1 | overheat error |
LED 5+4+2+1 | overload protection |
LED 3+2+1 | Outdoor unit pipe sensor |
LED 5+3+2+1 | icing protection |
LED 5+4+3+1 | Defrost protection |
LED 2+1 | Compressor heater active |
LED 5+2+1 | Bypass valve active |
Vestel SST Hall type air conditioner fault codes
E1 | Indoor temperature sensor malfunction |
E3 | Indoor unit pipe sensor malfunction |
E4 | Compressor outlet temperature sensor malfunction |
F1 | Phase protection (Phase sequence) |
Vestel inverter air conditioner fault codes
Er01 | Indoor unit ambient sensor |
Er02 | Indoor unit AC Supply Voltage error |
Er03 | Indoor unit pipe sensor error |
Er04 | Indoor unit Fan error |
Er05 | Indoor unit eeprom error |
Er06 | Indoor/Outdoor signal cable error |
Er07 | Gas leak |
Er08 | Outdoor unit pipe sensor Outdoor unit light flash 8. stop 3 sec |
Er09 | Indoor/Outdoor unit signal error Outdoor unit light flash 9. stop 3 sec |
Er010 | Compressor low speed error Outdoor unit light flash 10. stop 3 sec |
Er011 | Over Current fault Outdoor unit light flash 11. stop 3 sec |
Er012 | PFC Error Outdoor unit light flash 12th stop 3 sec |
Er013 | inverter signal error Outdoor unit light flash 13. stop 3 sec |
Er014 | IPM and inverter error Outdoor unit light flash 14. stop 3 sec |
Er015 | Outdoor unit ambient sensor Outdoor unit light flash 15. stop 3 sec |
Er016 | Compressor discharge line sensor Outdoor unit light flash 16th stop 3 sec |
Er19 | Compressor start error Outdoor unit light flash 19. stop 3 sec |
Er20 | Outdoor unit system error Outdoor unit light flash 20. stop 3 sec |
HL | AC Supply voltage error Outdoor unit light flash 1st stop 3 sec |
OT | Outdoor temperature too high Outdoor unit light flash 2nd stop 3 sec |
ON | Outdoor Pipe sensor Excessive high Outdoor unit light flash 3rd stop 3 sec |
00 | Compressor discharge temperature Too high Outdoor unit light flash 4. stop 3 sec |
OH | IPM Temperature Too high Outdoor unit light flash 5th stop 3 sec |
Vestel display air conditioner
Operation led (1) Timer led (2) Fan led (3) Turbo led (4)
Led 2 | Indoor unit ambient sensor |
Led 1+2 | Indoor pipe sensor |
Led 3 | indoor unit fan |
Led 1+3 | Gas leak |
Led 1+4 | voltage high/low |
Led 1+2+3+4 | Electronic card memory erased |
Timer Lamp is flashing | abnormality in serpentine censors |
E57 | Insufficient refrigerant, lack of gas, copper pipe broken in the intermediate installation, Compressor pressure low |
Both RUN and Timer lamps are flashing | Abnormality of outdoor unit, compressor malfunction, capacitor malfunction, insufficient refrigerant. gas missing |
Fault code fault led indoor/outdoor unit malfunction cause will be checked
1.led lights up once and goes off for 3 seconds | indoor thermistor replace indoor thermistor |
2.led lights up 2 times and goes off for 3 seconds | outdoor unit thermistor replace outdoor unit thermistor |
3.led turns on 3 times and goes off for 3 seconds | Operation error in both heating and cooling in multi split |
4.led lights up 4 times and goes off for 3 seconds | Compressor open circuit comp. Check |
5.led turns on 5 times and goes off for 3 seconds | Communication error check interconnection cables |
6.led lights up 6 times and goes off for 3 seconds | dc peak 2 error over current in inverter air conditioner power tr |
7.led turns on 7 times and goes off for 3 seconds | ct2 error (inverter air conditioner) check return gas pressure |
8.led lights up 8 times and goes off for 3 seconds | Fan not working check fan motor and control circuit |
10.led turns on 10 times and goes off for 3 seconds | Compressor dome thermistor error check dome |
12.led lights up 12 times and goes off for 3 seconds | Check for incorrect connection pipe and cable connections |
Protection Messages
dF: The icing on the outdoor unit is being defrosted. After the defrosting operation is accomplished, your air conditioner will continue to operate in the heating mode, the product should not be turned off while this mode is enabled.
RE: Make the arc control for your electrical wiring, if the problem is not fixed call for the service. If the problem comes out very frequently, contact with the authorised service.
Sr: In case of certain failures, in order to not to spoil you comfort, your air conditioner continues to operate despite the failure. In that case, you don’t need to turn your air conditioner off. It is needed to contact with the authorized service immediately
HL: There is a fluctuation in the electrical voltage, wait for its recovery.
ER11-ER13: The codes of ER-13 and ER-11, and the messages displayed on the indoor unit display, are protection messages in the aim of preventing the product from some harmful consequences resulting from an excessiv current coming from the compressor. The product turns off right after it enters into these protections. In the case that it is re-operated by the remote control, cooling and heating functions restart.
Troubleshooting
When you notice an abnormal situation in your air conditioner, you may attempt to troubleshoot according to the following instructions. If your air conditioner still do not work properly, contact with the Call Centre or the nearest Authorised Service. You may access the authorised services list and contact information from the web site.
Problem: The air conditioner is not running.
Reason:
- Power cut.
- On/off button is not turned on.
- The fuse is broken.
- Batteries of the remote have gone down.
- The time set to start running has not been reached.
- The remote control is not detecting.
- Light source is too close to the air conditioner.
Solution:
- Wait for the power to be back.
- Turn on the air conditioner.
- Have the fuse changed.
- Change the batteries.
- Wait or cancel the setting.
- Change the batteries.
- Some light sources that are close to the air conditioner, may prevent its functioning creating a magnetic influence. Retry to use the remote control after disabling the light source. If the problem is solved, it would be useful to change the light source.
Problem: The air conditioner is blowing air, but cooling and heating performance is bad.
Reason:
- There is a mistake in temperature setting.
- Air filter is clogged with dust.
- Air inlet or outlet of the air conditioner is blocked.
- Door and windows are open.
Solution:
- Set appropriate temperature. See application methods
- Clean up dust filters.
- Clean the materials that cause blocking.
- Close the windows and the doors.
Problem: Air flow does not start immediately during heating.
Reason: The necessary temperature for heating has not been reached.
Solution: If air flow starts before the temperature rises, an undesired cooling effect will occur. In order to prevent this, air flow will start after necessary temperature is reached. This is not due to a malfunction of the air conditioner and it is not a failure.
Problem: The air conditioner is blowing air, but it does not cool.
Reason:
- Air inlet or outlet of the air conditioner is blocked.
- Compressor protection (3 min).
- There is a mistake in temperature setting.
Solution:
- Clean the materials that cause blocking and restart the air conditioner.
- Wait.
- Set appropriate temperature.
Problem: There is clicking sound coming from the air conditioner.
Reason: Temperature change.
Solution: Changes in temperature cause expansion and contraction of plastic materials. This is not due to a malfunction of the air conditioner and it is not a failure.