Ideal Combi Boiler Error Codes

Ideal Combi Boiler Error Codes Even boilers have their bad days. Many different kinds of faults can develop with your Ideal boiler. Certain Ideal boiler problems lead the boiler to go into a safety lock-out mode after which fault code information is generated on the display. With proper Ideal boiler troubleshooting, you can identify different Ideal boiler fault codes and find an adequate solution.

Ideal Combi Boiler Error Code Solutions

What does my Ideal Boiler Fault Code mean?

İdeal Combi Boiler Error Codes can give us with a lot of information through their fault codes, helping professional engineers get a head start when undertaking a repair.

Logic Max & Logic Plus Regular/Logic Max System / Logic Plus System

Fault code System behaviourWhat to do? 
L1This means there may be an issue with the system water pressure or water flow.Make sure the pressure is between 1 and 1.5 bar on the pressure gauge. If the fault code is still there once you’ve increased/decreased the pressure, contact Ideal or BOXT so someone can take a further inspection.
F2, FN or LNThis means there may be an issue regarding flame loss.The first thing you should do is to examine if other gas appliances in your home are working normally, that way you’ll know for sure if there is a gas supply in the property. It’s worth checking that the gas supply is on at the meter, if the boiler still doesn’t turn on – then contact Ideal or BOXT.
L2Ignition lockoutFirstly, check any other gas appliances in your home are working normally to confirm the gas supply is operating. If the appliances don’t work, then check the gas supply at the meter. It would be a good idea to examine the pipe to make sure it hasn’t frozen. This is especially common during winter.
LCTurn power off and onAll you need to do is turn the boiler’s power off and on again.  If you have a Logic Max & Logic Plus Regular, try restarting your boiler five times in fifteen minutes. If you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.
F6This means that there is an issue with the outside sensor.Turn the boiler’s power off and on again. Once you’ve done this, if your boiler still isn’t operating correctly, then contact BOXT or Ideal.
F9, L9, F8 or L8There is an issue with the outside sensor.Turn the boiler’s power off and on again. Once you’ve done this, if your boiler still isn’t operating correctly, then contact BOXT or Ideal.

Logic Max & Logic Plus Regular

Fault code System behaviourWhat to do? 
LCTurn power off and onTry restarting your boiler five times in fifteen minutes. If you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.
L6There has been a false flame lockoutThis means that your boiler needs restarting. If your boiler still isn’t operating correctly when you’ve done this, then contact BOXT or Ideal.
FAThe pump has potentially been installed the wrong way around.You should contact either Ideal or BOXT to make a further inspection.
FDNo water flowMake sure the pressure is between 1 and 1.5 bar on the pressure gauge. If the fault code is still there once you’ve increased/decreased the pressure, contact Ideal or BOXT so someone can take a further inspection.

Logic Max & Logic Plus Regular / Logic Max System / Logic Plus System

Fault codeSystem behaviourWhat to do? 
F2 or FN or LNThere is an issue with flame loss.In this case, all you need to do is turn the boiler’s power off and on again. If you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.
L4 or F4This means that there is a no flow thermistor fault.Turn the boiler’s power off and on again. Once you’ve done this, if your boiler still isn’t operating correctly, then contact BOXT or Ideal.
F7This signifies that you have low mains voltage.To sort this you’ll need to contact an electrician or your electricity provider.
FUThis means there is a water circulation issue. This signifies that there could be an airlock or blockage within the system.To resolve this you should check that the isolation valves are open. Once you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.

Logic Max System / Logic Plus System

Fault codeSystem behaviourWhat to do?
F3Signifies an issue with the fan.Turn the boiler’s power off and on again. Once you’ve done this, if your boiler still isn’t operating correctly, then contact BOXT or Ideal

Logic Max Plus Combi

Fault codeSystem behaviourWhat to do?
‘Overheat lockout’There is likely to be an issue with water pressure or a blockage in the system.You should bleed your radiators and ensure the pressure gauge on the boiler is at 1.0 bar.

Also, you should check that the boiler valves are open and reset the boiler. Once you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.

‘Ignition lockout’Check gas appliances work and restart the boilerAll you need to do is turn the boiler’s power off and on again to restart the boiler.

Also, you should check that any other gas appliances are working as normal, to confirm that your gas supply is present. Once you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.

‘Too many resets’5 starts within 15 minutesTurn the power off and on and do this five times within fifteen minutes. Once you’ve done this, if your boiler still isn’t operating correctly, then contact BOXT or Ideal.
‘Flame on before gas on’False flame lockoutAll you need to do is turn the boiler’s power off and on again. Once you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or Ideal.
‘Water pressure’Likely to be an issue with water pressure or a blockage in the system.

You should bleed your radiators and ensure the pressure gauge on the boiler is between 1.0 and 1.5 bar. Once you’ve done this and your boiler still isn’t operating correctly, then contact BOXT or