MRCOOL Air Conditioner Error Codes With this A/C troubleshooting guide, you can find problems with your system, fix it yourself. We will guide you through the process of identifying the problem and repairing your air conditioner.
MRCOOL Air Conditioner Error Code Solutions
Overview: Fault Display on the Dual 8 Numeral Tube of Outdoor Mainboard
Error Codes | Meaning |
---|---|
E1 | Actuation of high pressure switch |
E3 | Actuation of low pressure switch |
E4 | Air discharge high temperature protection of compressor |
F2 | Malfunction of condenser temperature thermistor |
F3 | Malfunction of outdoor ambient temperature thermistor |
F4 | Malfunction of Exhaust Temp. Sensor |
oN | Normal operation |
H1 | Defrost operation |
How to Fix?
Error Code: E1
Trouble Case: Actuation of high pressure switch
Origin of Trouble Signal: High pressure switch
Measure: Abnormality is detected when the contact of the high pressure switch opens for 3 sec. The system will be shut down. The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Error Code: E3
Trouble Case: Actuation of low pressure switch
Origin of Trouble Signal: Low pressure switch
Measure: When the unit runs more than 4 minutes or does not run, the low pressure switch opens for more than 3sec and the system will be shut down. The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Error Code: E4
Trouble Case: Air discharge high temperature protection of compressor
Origin of Trouble Signal: Exhaust over temperature protection
Measure: The exhaust temperature is higher than 125°C for more than 5sec, the system will be shut down. After stopping the compressor for 3 mins, if the exhaust temperature is lower than 90°C for more than 5 sec, the compressor will re-start. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Error Code: F2
Trouble Case: Malfunction of condenser temperature thermistor
Origin of Trouble Signal: Condenser temperature thermistor
Measure: Malfunction of condenser temperature thermistor is detected when there is a short circuit or an open circuit in the condenser temperature thermistor for more than 5 sec. The system will be shut down. The reset for the malfunction of condenser temperature thermistor is automatic.
Error Code: F3
Trouble Case: Malfunction of outdoor ambient temperature thermistor
Origin of Trouble Signal: Outdoor ambient temperature thermistor
Measure: Malfunction outdoor ambient temperature thermistor is detected when there is a short circuit or an open circuit in the outdoor ambient temperature thermistor for more than 5 sec. The system will be shut down. The reset for the malfunction of condenser temperature thermistor is automatic.
Error Code: F4
Trouble Case: Malfunction of Exhaust Temp. Sensor
Origin of Trouble Signal: Exhaust temperature sensor
Measure: If the exhaust temperature sensor is detected of open circuit 5 seconds successively after the compressor is started for 2 minutes or short circuit 5 seconds successively at any time .The system will be shut down. After the fault is eliminated, the system can automatically resume to operation.
Error Code: oN
Trouble Case: Normal operation
Origin of Trouble Signal: Unit operating normally or in standby mode.
Error Code: H1
Trouble Case: Defrost operation
Origin of Trouble Signal: Unit operating in defrost
Error Analysis
Trouble Case: Power problem
Measure:
- Check control transformer power (24V).
- If power is available to demand control board and LED(s) do not light, replace control board.
Trouble Case: Actuation of high pressure switch
Measure: Abnormality is detected when the contact of the high pressure switch opens for 3 sec. The system will be shut down. The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Trouble Case: Actuation of low pressure switch
Measure: When the unit runs more than 4 minutes or does not run, the low pressure switch opens for more than3sec and the system will be shut down..The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Trouble Case: Air discharge high- temperature protection of compressor
Measure: The exhaust temperature is higher than 125°C for more than 5s, the system will be shut down. After stopping the compressor for 3 mins, if the exhaust temperature is lower than 90°C for more than 5s, the compressor will re-start. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.
Trouble Case: Malfunction of exhaust Temp. Sensor
Measure: If the exhaust temperature sensor is detected of open circuit 5 seconds successively after the compressor is started for 3 minutes or short circuit 5 seconds successively at any time The system will be shut down. After the fault is eliminated, the system can automatically resume to operation.
For 13 SEER R410A Unitary Ducted Split AC & Heat Pump
Olympus Series Mid-Static Duct Air Handler
Fault Codes | Solutions |
---|---|
E0 | Indoor EEPROM error |
E1 | Communication malfunction between indoor and outdoor units |
E3 | Indoor fan speed malfunction |
E4 | Indoor room temperature sensor open circuit or short circuit |
E5 | Evaporator coil temperature sensor open circuit or short circuit |
EC | Refrigerant leakage detection malfunction |
EE | Water-level alarm malfunction |
E8 | Communication malfunction between two indoor units (for twins model) |
E9 | Other malfunction of twins model |
F0 | Current overload protection |
F1 | Outdoor room temperature sensor open circuit or short circuit |
F2 | Outdoor condenser pipe temperature sensor error |
F3 | Discharging air temperature sensor error |
F4 | Outdoor EEPROM error |
F5 | Outdoor fan speed malfunction (Only for DC fan motor) |
F6 | T2b sensor error |
P0 | Inverter module IPM protection |
P1 | High/Low voltage protection |
P2 | High temperature protection of compressor top |
P3 | Outdoor low temp. protection |
P4 | Compressor drive error |
P5 | Mode conflict |