Westinghouse Air Conditioner Error Codes Please read all of the instructions before using the air conditioner and keep this manual for future reference. The air conditioner you purchased has R410a gas refrigerant a environmental friendly gas which does not damage the ozone layer.
Westinghouse Air Conditioner Error Code Solutions
Error signals on the display:
In case of error, the display on the indoor unit shown the following error codes:
Error Codes | Description of the trouble |
---|---|
E0 | Indoor unit EEPROM parameter error. |
E1 | Indoor / outdoor units communication error. |
E2 | Zero-crossing signal detection error. |
E3 | Indoor fan speed has been out of control. |
E4 | Open circuit or short circuit of indoor room temperature T1 sensor. |
E5 | Open circuit or short circuit of evaporator coil temperature T2 sensor |
EC | Refrigerant Leakage Detection |
F1 | Open circuit or short circuit of outdoor ambient T4 temperature sensor |
F2 | Open circuit or short circuit of condenser coil temperature T3 sensor |
F3 | Open circuit or short circuit of compressor discharge T5 temperature sensor |
F4 | Outdoor unit EEPROM parameter error |
P0 | IPM malfunction or IGBT over-strong current protection |
P1 | Over voltage or over low voltage protection |
P2 | High temperature protection of compressor top diagnosis and solution |
P4 | Inverter compressor drive error |
Westinghouse Air Conditioner Troubleshooting
Malfunction: The appliance does not operate
Possible causes:
- Power failure/plug pulled out
- Damaged indoor/outdoor unit fan motor
- Faulty compressor thermomagnetic circuit breaker
- Faulty protective device or fuses.
- Loose connections or plug pulled out
- It sometimes stops operating to protect the appliance.
- Voltage higher or lower than the voltage range
- Active TIMER-ON function
- Damaged electronic control board
Malfunction: Strange odour
Possible causes: Dirty air filter
Malfunction: Noise of running water
Possible causes: Back flow of liquid in the refrigerant circulation
Malfunction: A fine mist comes from the air outlet
Possible causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes.
Malfunction: A strange noise can be heard
Possible causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Malfunction: Insufficient airflow
Possible causes:
- Unsuitable temperature setting.
- Obstructed air conditioner intakes and outlets.
- Dirty air filter.
- Fan speed set at minimum.
- Other sources of heat in the room.
- No refrigerant.
Malfunction: The appliance does not respond to commands
Possible causes:
- Remote control is not near enough to indoor unit.
- The batteries of remote control nearly has no power.
- Obstacles between remote control and signal receiver in indoor unit.
Malfunction: The display is off
Possible causes:
- Active LIGHT function
- Power failure
Malfunction: The display is off
Possible causes:
- Active LIGHT function
- Power failure
Malfunction: Switch off the air conditioner immediately and cut off the power supply in the event of:
Possible causes:
- Strange noises during operation.
- Faulty electronic control board
- Faulty fuses or switches.
- Spraying water or objects inside the appliance.
- Overheated cables or plugs.
- Very strong smells coming from the appliance.
E8 error Westinghouse Air Conditioner
E8 is usually caused by overheating and can be resolved by turning off the power to both the interior and outside unit.
Please what about solution to error code E3
An E3 Error Code is the indoor fan speed.
So please how can it get done please
What could be the possible solution to the error code E3
What is F6 on non inverter westinghouse unit please?
E9 error code on Westinghouse air conditioning
Error code e6
E9 air conditioner error westinghouse
what is the F0 or FO error code?