E01 Failure Failed Ignition Problem.

Solution Arçelik combi boiler fault codes, this error code is displayed on the screen when the ignition problem of this fault is experienced. In this case, you should first look at the gas inlets. That is, he must make sure that the gas valves are not closed. If it is closed, you must open it. Then you have to reset the device. If the problem is still not resolved, then what you need to do is to call the service. Because there may be an electronic card, ionization-ignition electrode problem, gas valve problem in the combi boiler. This situation can only be determined and resolved by the expert service team.

E02-F02 Fault Faulty Flame Formation Problem.

Solution In this error code, we can understand that the device is misfiring. In this case, you must first reset your boiler. If the problem persists after a maximum of 3 resets, you need to call the service. There may be a problem with the ionization electrode, electronic card or gas valve. For the solution, it is necessary to call the service and get help.

E03 Malfunction Overheating Problem.

Solution When the boiler is overheating, this error code is displayed on the screen. The limit thermostat activates due to overheating and blocks the boiler. In other words, the boiler will not operate in this fault code. In this case, first check the pressure of the combi, if the pressure is low, pour water into the combi. If this problem occurred while in the honeycomb position, check the honeycomb valves, if they are closed, open them. The important thing in this regard is the use of at least 3 honeycombs. Take care of this. If the problem still persists, reset the boiler. If the result does not change after the reset attempt, get service assistance. This problem may be experienced in cases where the three-way valve changes position-in the middle, there is calcification-clogging in the main heat exchanger, the circulation pump is jammed, the heating system is clogged or the heater filter is clogged.

E04-E05-E06-F23 Malfunction Prosestat Problem.

Solution This is the fault code indicating that there is a problem in the part that provides airflow control in the combi. Prosestat is a part available in hermetic combi boilers. It is in charge of informing the motherboard that there is no problem in the waste gas system with the positive pressure it receives from the fan. When it is faulty, it cannot do this task and there is an air flow problem in the combi boiler. The only reason is not related to the processstat. There may also be situations such as the chimney being dislodged, the fan being faulty or the electronic card having a problem. In this case, expert support should be sought.

E08-E82 Fault Ionization Problem.

Solution The ionization problem in the combi boiler means that the flame is not detected. If there is a problem of not detecting a flame, there may be a problem in the ionization electrode, electronic card or gas group. In this case, you should definitely seek expert Arçelik Service help for detection and solution.

E09 Malfunction Gas Valve Feedback Problem.

Solution In this case, the gas valve problem may occur. The gas valve is one of the important parts, especially in ignition. If there is a feedback problem, the device cannot successfully ignite. In this case, the problem may be in the electronic board together with the gas valve. You should call the service for detection and solution.

E12-E21-F25 Fault Electronic Board Problem.

Solution This error code appears on the screen when there is a problem with the brain card, which undertakes the management of all parts in the boiler and receives commands to operate the parts. In this case, there is no application that you have to do as a user. Since the part will need to be repaired or replaced, you should call Arçelik Service and ask for help.

F13 Failure Reset Locking Problem

Solution When the reset button on the combi is locked, this error code is displayed on the screen. In this error, we can say that the reset button of the device was pressed for a long time accidentally or the button was stuck. For solution, you should turn the device off from the power supply (switch) and start it again. The problem will be fixed.

F22 Fault Arçelik Combi Fault Codes Reports That There Is A Low Voltage Problem For This Fault.

Solution Combi boiler works with mains voltage. Especially in the winter periods, this problem occurs because the voltages are unstable, that is, one low and one high. You should wait for a while with the thought that the voltage will recover. If the problem persists, you should call the service. Parts of the device, especially the electronic card, may be burned or damaged. For this reason, it is useful to get service support in order to intervene in the problem. You can also use a regulator device in order not to experience this problem again or to experience it at all.

F31 Fault Central Heating Sensor Problem.

Solution It may be that the sensor, which is in the task of measuring the heating water temperature, is malfunctioning, that there is a break in the cables-short-circuit conditions, as well as dampening in the pipes. In such cases, on-site detection is required. Be sure to call the service.

F32 Fault Outside Air Sensor Problem.

Solution The outside air sensor is a part that is not found in every combi boiler. It is usually installed outside and operates the boiler according to the outside weather conditions. If there is an outside air sensor in your boiler, we can say that it is faulty. Otherwise, the probable cause is electrical failure. We recommend that you seek service assistance, as on-site detection and intervention will be required.

F33 Fault Domestic Water Sensor Problem.

Solution This is the error code that appears on the screen when there is a problem with the sensor that is in charge of measuring the temperature of the water at the hot water intake in the combi. Sensor failure is not the only reason for this situation. This fault code may also appear on the screen due to problems in the sensor cables or moisture in the sensor tube. In such cases, you should definitely seek professional help.

F37 Failure Low Water Pressure Problem.

Solution This is the error code indicating that the water in the boiler installation is low and the boiler needs water. In this case, you do not need service support. You need to flood the device with the blue filling tap at the bottom left. The water pressure should be adjusted to be between 1 and 2 bars. In this way, you will see that the combi returns to normal when you press water. If there is no improvement, you should reset the device and if the problem still persists, you should call Arçelik Service and get help.

F59 Fault Arçelik Combi Fault Codes Indicate There Is A Gas Valve Problem For This Fault.

Solution Arçelik boiler fault codes are the fault codes that we can understand when there is a problem in the gas valve, which is an important part that provides the gas path, when the boiler needs ignition. In this case, there is a break in the part. Or there may be a problem with the motherboard. In this case, seek professional help. There is no action or intervention that you can do as a user.