Baltgaz Gas Boiler Error Codes

Baltgaz Gas Boiler Error Codes Error code F 01 Indicates a failure of the ignition mechanism. The ionization flame sensor signals a failure in the device. This component analyzes the presence of a flame and interrupts the operation of the Baltgaz boiler during insufficient combustion of the main gas burner device or in cases of a failure in the gas supply. Blocking occurs after 3 unsuccessful inclusions. To resume work, you must press and hold the restart key.

Baltgaz Boiler Error Code Solutions

Gas valve failure – The gas valve is electronically controlled. Diagnostics of this component is carried out by measuring voltage and resistance. If it is found that the values ​​differ from the standard characteristics, it is necessary to replace the valve with a working one. Gas does not enter the unit – There is a valve in the gas distribution device that shuts off the gas supply. Consequently, a failure at the start of the device may appear due to a closed tap. Poor contact or no pulse from the ionization flame sensor. The control board is faulty – When the ignition occurred normally, but the device died out immediately in any case, then apparently the electronics do not detect the flame. Therefore, it is recommended to make its diagnosis.

Baltgaz Boiler Error Code F 02

Overheating of the boiler Baltgaz. The unit stops working. The overheating safety thermostat has tripped – The temperature sensor and the overheating thermostat are most often located on the outlet pipe of the primary heat exchanger. The main purpose of the thermostat is to protect the boiler unit from unnecessary temperature rise. Failure most often occurs due to problems in the thermostat, temperature sensor, as well as in case of malfunctions of the main circulation circuit.

Temperature sensor problems – The electronic board receives an incorrect signal or the contact between the electronic board and the sensor is broken. The overheating thermostat is out of order – If the sensor is working, but the actual overheating of the liquid is recorded, then it seems that there is a problem with the circulation of the coolant in the main circuit. There is a blockage in the primary heat exchanger or the main circuit filter (lack of circulation means increased heating of the liquid). Damage to the circulation pump or there is an air lock in the heating system.

Baltgaz Boiler Error Code F 04

Means that the pressure inside the system is reduced. The main factors due to which this malfunction occurs: a decrease in water pressure in the heating system. Lack of contact between the electronic board and the pressure switch. The pressure switch has failed. Initially, you need to check the values ​​\u200b\u200bof the pressure gauge. As a rule, the problem is eliminated using a make-up valve, which is installed to fill the heating system with coolant. When the fault reappears, there is most likely a fluid leak. The hydraulic pump, main heat exchanger, relief valve, worn seal elements, make-up valve and other components can leak. Leakage can be detected when inspecting hydraulic systems and components.

Baltgaz Boiler Error Code F 03

Lack of traction. For the stable and safe operation of the Baltgaz boiler, it is recommended to organize draft for flue gases to prevent them from entering the room. This is monitored by automation, and if any problems arise, the draft sensor turns on and the device stops working. Probable reasons for the lack of draft: insufficient size of the flue duct, improper installation, blockage, icing of the inner wall. Reducing the size of the chimney leads to weak draft. The length of the flue pipes has been exceeded. It is recommended that you carefully study the operating instructions for the device and comply with all necessary requirements.

Too long a horizontal section of the smoke exhaust pipe causes a lack of draft. Malfunction with pneumatic relay-draft sensor – If a vacuum occurs in the supply pipe, a soft click will be heard. There is no contact of the control board with the pneumatic relay-traction sensor, there is condensate, as well as poor fastening of the tubes with the pneumatic relay. Damaged fan parts – The fan impeller is clogged. There is no lubrication on the fan shaft, which is why it does not increase the required speed. There is no contact between the fan and the electronic board.

Baltgaz Boiler Error Code F 06

Failure to determine the temperature by the DHW sensor. This indicates that there is a malfunction of the DHW circuit temperature sensor or the temperature required for operation has greatly increased. The main factors for the appearance of this malfunction: the DHW temperature sensor is broken. Poor contact between the electronic board and the DHW temperature sensor. Damage to the electronic board. If the hot water temperature sensor is good and connects correctly to the electronic board, but the boiler gives an error, then it looks like the electronic board is out of order.

Baltgaz Boiler Error Code F 09

Ignition is not performed. This can occur when the ignition does not work or the burner flameout is observed. It is required to inspect the contacts between the ignition mechanism and the flame electrode, and also between the control board and the gas valve. One of the reasons for the failure of the flame may be unsatisfactory draft.

Baltgaz Boiler Error Code F 05

Refusal to determine the temperature by the heating system sensor. This code indicates that the temperature sensor of the heating system has broken down or the allowable temperature has greatly increased. An open in the heating system temperature sensor circuit – This problem most often occurs when the contact of the temperature sensor with the electronic board is interrupted, or the temperature value is lower than recommended. 5 seconds after the recognition of the malfunction, the Baltgaz boiler should resume normal operation, in case the malfunction occurred spontaneously.

It is necessary to make sure that there is no moisture on the sensor connector and the electronic board connector. If there is no moisture, the temperature sensor must be replaced. There is a short circuit of the temperature sensor of the heating circuit – This failure most often occurs when the contacts of the temperature sensor are short-circuited or the temperature of the water is higher than recommended. First you need to measure the resistance of the sensor. If the resistance values ​​differ from the nominal values, it is necessary to replace the sensor. If installing a new sensor does not work, replace the control board.