Fedders Air Conditioner Error Codes Upon receipt of equipment, check carton for visible damage. Make a notation on the shipper’s delivery ticket of any damages before signing.
Fedders Air Conditioner Error Code Solutions
If there is any evidence of rough handling, the cartons should be opened at once to check for concealed damage. If any damage is found, notify the carrier within 48 hours to establish your claim, and request an inspection report from the carrier. The warranty claims department should then be contacted.
Error Codes | Cause |
---|---|
E1 | System high pressure protection |
E2 | Anti-freezing protection |
E4 | Compressor air exhaust high temp. protection |
E5 | AC overload protection |
E6 | Indoor and outdoor units communication malfunction |
E8 | Anti-high temp. protection |
H6 | Indoor unit motor no feedback |
C5 | Jump wire cap malfunction protection |
F1 | Indoor ambient sensor open circuit, short circuit |
F2 | Indoor evaporator sensor circuit open, short circuit |
F3 | Outdoor ambient sensor circuit open, circuit short |
F4 | Outdoor condensor sensor open circuit, short circuit |
F5 | Outdoor air exhaust sensor open circuit, short circuit |
F6 | Overload limit/descending frequency |
F8 | Over current need frequency descending |
F9 | Air exhaust over high need frequency descending |
PH | DC generatrix voltage is too high |
U5 | Whole unit’s current testing malfunction |
P5 | Compressor current overcurrent protection |
H1 | Defrosting |
H2 | Electrostatic dedust protection |
H3 | Compressor overload protection |
H4 | System is abnormal |
H5 | IPM protection |
HC | PFC protection |
H7 | Compressor lose steps |
H0 | Heating, anti-high temp. declines |
Lc | Startsup fail |
U1 | Compressor current testing circuit malfunction |
EE | EEPROM malfunction |
PU | Capacitor charge malfunction |
P7 | Module sensor circuit diagram |
P8 | Module temp. over high protection |
U3 | DC Bus voltage dips |
PL | Low DC Bus voltage protection |
EU | IPM temp. is too high limit/decrease frequency |
U7 | Four-way valve abnormal |
U9 | Outdoor unit zerocross detecting error |
FH | Anti-freezinglimit/decreasefrequency |
FEDDERS LARGE SPLIT UNIT (R407C)
Fedders Air Conditioner Troubleshooting
Air conditioner will not operate
Possible Cause:
- Wall plug disconnected.
- House fuse blown or circuit breaker tripped.
- Unit turned off and then on too quickly.
- Thermostat set too low for cooling.
Solutions:
- Push plug firmly into wall outlet.
- Replace fuse with time delay type or reset circuit breaker.
- Wait 3 minutes before restarting.
- Adjust thermostat to lower temperature
Air from unit does not feel cold enough
Possible Cause:
- Unit in Fan mode.
- Temperature set too high.
- Room temperature below 70°F
Solutions:
- Set Mode to Cool.
- Set thermostat to lower temperature.
- Cooling may not occur until room temperature rises above 70°F.
Air conditioner cooling, but room is too warm ice forming on cooling coil behind decorative front
Possible Cause:
- Outdoor temperature below 70°F.
- Dirty air filter air restricted.
Solutions:
- To defrost the coil, set mode to Fan. Then, set thermostat to warmer temperature.
- Clean filter.
Air conditioner cooling, but room too warm – NO ice forming on cooling coil behind decorative front
Possible Cause:
- Dirty air filter air restricted.
- Thermostat set too warm.
Solutions:
- Clean air filter.
- Set thermostat to colder temperature.
Noise when unit is cooling
Possible Cause:
- Air movement sound.
- Sound of fan hitting watermoisture removal system.
- Window vibration poor installation.
Solutions:
- The sound of rushing air is normal. If too loud, Fan Speed to Low setting.
- This is normal when humidity is high. Close doors, windows and registers.
- Refer to installation instructions check with installer