Ariston Combi Boiler Error Codes

Ariston Combi Boiler Error Codes Now, back to the Ariston boilers. Check out the table below to find your error code and see what the fault code on your Ariston boiler relates to. Ariston fault codes are generally the same across all their boilers, which makes it easier to identify the issue with your boiler.

Ariston Boiler Error Code Solutions

Fault CodeBoiler ModelPossible Cause
Central Heating Circuit Issues
101All BoilersOverheat
102E-Combi Evo
E-System Evo
Clas He Evo (Combi and system)
Pressure sensor error
103All BoilersInsufficient circulation
104All BoilersInsufficient circulation
105All BoilersInsufficient circulation
106All BoilersInsufficient circulation
107All BoilersInsufficient circulation
108All Combi BoilersInsufficient water (request filling)
109Clas net one / Clas one Combi
Clas system one
System pressure greater than 3 bar
110All BoilersCentral heating Flow temperature probe circuit open/short circuit
112All BoilersCentral heating Flow temperature probe circuit open/short circuit
114All BoilersExternal sensor circuit open/short circuit
116All Combi and System BoilersFloor thermostat contact open
118All BoilersHeating delivery probe problem
1p1All BoilersInsufficient circulation indication
1p2All BoilersInsufficient circulation indication
1p3All BoilersInsufficient circulation indication
1p4Clas Net one Combi
Clas one Combi
Clas System one
Insufficient circulation indication

 

Fault CodeBoiler ModelPossible Cause
Hot Water Circuit Issues
202Clas HE evo
Clas he evo system
E-combi evo
E-system evo
2 bottom storage temperature probe open/short circuit
204Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Solar collector temperature probe open/short circuit
205E-combi one
E-System one
Clas Net one Combi
Clas one Combi
Domestic hot water in probe open circuit
207Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Solar collector overheating
208Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Collector frost protection temperature

 

Fault CodeBoiler ModelPossible Cause
Internal Printed Circuit Board (PCB) Issues
301All BoilersEEPROM error
302All BoilersCommunication error
303All BoilersMain printed circuit board (PCB) error
304All BoilersToo many resets (> 5) in 15 minutes
305All BoilersMain printed circuit board (PCB) error
306All BoilersMain printed circuit board (PCB) error
307All BoilersMain printed circuit board (PCB) error
3p9E-combi one
E-System one
Clas Net one Combi
Clas one Combi
Clas System one
Schedule service
External Printed Circuit Board (PCB) Issues
407Clas HE evo
Clas he evo system
E-combi evo
E-system evo
7 Room sensor circuit open/short circuit

 

Fault CodeBoiler ModelPossible Cause
Ignition & Detection Issues
501All BoilersNo flame detected
502All BoilersFlame detected with gas valve closed
504All BoilersFlame lift
5p1All Boilers1st ignition failed
5p3All Boilers2nd ignition failed
5p4All BoilersFlame cut-off

 

Fault CodeBoiler ModelPossible Cause
Air Inlet / Flue / Gas Outlet Issues
604CLAS HE R
E-Combi Evo
E-System EVO
Clas HE evo Combi
Clas HE evo System
Insufficient fan speed
610All BoilersThermofuse open
612Clas HE Evo Combi
Clas He Evo System
E-Combi Evo
E-system Evo
Clas net one combi
Clas one combi
Clas system one
Fan speed has incorrect measurement

 

Fault CodeBoiler ModelPossible Cause
Multi-Zone Heating Issues
701E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 2 outgoing sensor defective
702E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 2 return sensor defective
703E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 3 outgoing sensor defective
704E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 3 return sensor defective
705E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Hydraulic separation sensor defective
706E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 2 overheating
707E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 3 overheating

Ariston System Boiler Error / Fault Codes – Clas Net One, Clas One, E-Combi and E-System Boilers

Fault CodeBoiler ModelPossible Cause
External Printed Circuit Board (PCB) Issues
411Clas Net one
Clas one
E System
Room sensor circuit open or short circuit zone 1
412Clas Net one
Clas one
E System
Room sensor circuit open or short circuit zone 2
414Clas Net one
Clas one
E System
Room sensor circuit open or short circuit zone 3
Multi-Zone Heating
701Clas Net one
Clas one
E System
Send sensor defective (Zone 1)
702Clas Net one
Clas one
E System
Send sensor defective (Zone 2)
703Clas Net one
Clas one
E System
Send sensor defective (Zone 3)
711Clas Net one
Clas one
E System
Return sensor defective (zone 1)
712Clas Net one
Clas one
E System
Return sensor defective (zone 2)
713Clas Net one
Clas one
E System
Return sensor defective (zone 3)
722Clas Net one
Clas one
E System
Overheating in zone 2
723Clas Net one
Clas one
E System
Overheating in zone 3
750Clas Net one
Clas one
E System
All heating zones locked

Leave a Reply