Baltur Gas Boiler Error Codes Gas boilers are the most efficient and economical for providing heating and domestic hot water. These advantages are achieved through the use of modern components and advanced automation. Various sensors not only monitor the status of the heating system, but also monitor changes in the environment. And in case of failure, the security system takes measures to eliminate the threat: it stops the fuel supply and stops the equipment from working.
Baltur Boiler Error Code Solutions
Baltur Boiler Error Code E01
It means that the ignition is blocked. The ionization flame sensor, which monitors the ignition, reports a malfunction. Such an element detects the presence of a flame and interrupts the operation of the Baltur boiler in case of weak combustion of the main burner or in case of failures in the gas supply. The termination of work occurs after 3 unsuccessful launches. To resume operation, you must press and hold the Reset button. Faulty gas valve – The gas valve is controlled by an electronic board.
This component is tested by determining the resistance and voltage values. If it turns out that the values differ from the standard parameters, it is recommended to replace the valve with a working one. No gas flow into the system – There is a valve in the gas distribution system that closes the inflow of gas fuel. Therefore, an accident at the time of starting the boiler can be observed due to a closed tap. Incorrect contact or no signal detected from the ionization flame sensor. The control board has a malfunction – If the ignition cycle is performed normally, but the device goes out immediately anyway, then most likely the control board does not fix the flame. In this case, you need to check it.
Baltur Boiler Error Code E02
Overheating of the Baltur boiler. The device is blocked. The overheating thermostat is triggered – The overheating thermostat as well as the temperature sensor are in most cases installed on the outlet pipe of the primary heat exchanger. The functional task of the thermostat is to protect the boiler unit from elevated temperatures. The malfunction appears due to problems with the thermostat, temperature sensor, and in addition, in case of malfunctions of the main circulation circuit.
Temperature sensor failure – The electronic board receives an incorrect signal or poor contact between the electronic board and the sensor. Failure of the overheat thermostat – When it is operational, but the actual superheat of the liquid is determined, then most likely there is a problem with the circulation of the coolant of the main circuit. Clogged main heat exchanger or heating circuit filter element (weak circulation means increased heating of the coolant). The circulation pump is out of order or there is a blockage from the air in the heating system.
Baltur Boiler Error Code E10
Indicates low pressure inside the system. Probable causes influencing the formation of this malfunction: low fluid pressure in the heating circuit. There is no contact between the control board and the minimum pressure switch. Pressostat malfunction. First you need to look at the results of the pressure gauge. In many cases, the problem can be eliminated by means of a make-up tap, which is designed to fill the heating circuit with water. If the problem repeats again, then there may be a coolant leak. The hydraulic pump, the main heat exchanger, the emergency overpressure relief valve, damaged gaskets, the feed valve and other parts can leak. Leakage is determined at the time of external inspection of hydraulic components and connections.
Baltur Boiler Error Code E03
Weak traction. In order to ensure the correct and trouble-free operation of the apparatus, it is necessary to create a draft for the removal of flue gases so that they do not penetrate into the living quarters. The outlet of gases is controlled by automatics, and if any problems appear, the draft sensor is triggered and the unit will be turned off. Possible reasons why there is no draft: small-sized diameter of the flue duct, defect during installation, pollution, icing of the inner wall. The narrowing of the diameter of the flue duct can cause a lack of draft. The length of the chimney pipe has been exceeded.
We advise you to carefully read the instructions for using the gas boiler and comply with the relevant requirements. A sufficiently long horizontal section of the flue pipe often causes a lack of draft. The pressure switch-draft sensor is damaged – If a vacuum occurs in the inlet tube, a slight click will be noticeable. There is no contact between the pressure switch and the control board, the presence of condensate, as well as incorrect fastening of the tubes with the pneumatic relay.
Incorrect fan operation – There is a blockage in the fan impeller. Lack of sufficient lubrication of the fan shaft, and therefore it cannot develop the required speed. The contact between the fan and the electronic board is broken. in connection with which he cannot develop the necessary speed. The contact between the fan and the electronic board is broken. in connection with which he cannot develop the necessary speed. The contact between the fan and the electronic board is broken.
Baltur Boiler Error Code E06
Malfunction of the hot water temperature sensor. This circumstance indicates the failure of the temperature sensor of the DHW circuit or the required temperature has greatly increased. The main factors due to which this problem may appear: the temperature sensor for hot water supply is damaged. There is no contact between the control board and the DHW temperature sensor. Failure of the electronic board. When the DHW temperature sensor is intact and firmly connected to the control board, although the boiler displays an error, then it looks like the electronic board needs to be replaced.
Baltur Boiler Error Code E35
Problems at the time of ignition. This situation is displayed when the ignition mechanism does not work or the flame breaks off. It is necessary to inspect the connections between the ignition unit and the flame sensor, and also between the electronic board and the gas valve. The main reason for the extinction of the burner flame is unsatisfactory draft.
Baltur Boiler Error Code E05
The temperature sensor on the heating system does not work correctly. This situation means that the temperature sensor of the heating system is damaged or the required temperature has risen. Open circuit of the temperature sensor in the heating circuit – Such a malfunction occurs when the connection between the temperature sensor and the electronic board is broken, or the temperature is below the nominal value. 5 seconds after the recognition of a malfunction, the Baltur boiler must return trouble-free operation, in case the malfunction occurred spontaneously. It is recommended to make sure that there is no moisture on the sensor connector and the electronic board connector.
If there is no moisture, the temperature sensor needs to be replaced. There is a short circuit in the heating circuit temperature sensor – This problem can occur after a short circuit in the temperature sensor circuit or the water temperature is much higher than required. The first step is to measure the resistance of the sensor. If the resistance characteristics do not correspond to the required ones, it is necessary to replace the sensor. If replacing the temperature sensor does not work, repair the board.
The Baltur boiler is in operation. In the last week, the error code E01 lights up almost regularly. After resetting with the reset button, the device starts up normally from time to time, but this happens sporadically. A few days ago I removed the air plug and it started to function better. What is this breakdown?
If it gives an error on the chimney, you need to open the protective covers. This will help air flow out of the room. Following this, inspect the chimney for the presence of ice and, if any, remove it. In the event of a fire-related accident, you need to check whether gas is getting into the house.
Often the error E05 is displayed on the boiler. Can you help me figure out what she’s talking about?
This code refers to problems with the heating temperature sensor. It probably needs to be changed.
What is the problem if the Baltur boiler cannot start? In this case, error E02 periodically lights up. What to do?
This failure can be shown due to various problems with the thermostat, temperature sensor, and also in case of malfunctions in the main circulation circuit. It looks like there is overheating of the water in the heat exchanger. If the temperature sensor and thermostat are not damaged, then the problem is with the electronic board. It needs to be replaced.
What is the problem if the boiler cannot start and gives the error code E10? Pressure normally holds, leaks are not observed. I disconnect from the network, but the problem is not removed. What is the cause of the problem?
The fault code may indicate low water pressure in the heating circuit. With this problem, it is necessary to check the minimum pressure switch. He must be broken.
The problem of the unit looks like this: the DHW is adjusted to forty degrees. If you use hot water, the burner lights up and then goes out. This cycle continues on a regular basis. Warm water flows from the tap, then cold. From time to time error E02 is displayed. For what reason did this happen?
This failure is a sign of overheating of the DHW coolant. It looks like the heat exchanger is clogged, and the thermostat has settings other than recommended.
The following problem has occurred. When ignited, the unit gives an error E35 (breaks the flame). If you restart it, it turns on, but the burner barely ignites, you can hear incomprehensible clicks, and then an error is displayed. I replaced the ionization electrode, washed the flow sensor, removed the earth from the plug, but there was no result. Has anyone met with this?
This problem occurs for three reasons. Control electrode defective. Incorrect gas supply. Damaged electronic board.
The unit has stopped working autonomously and code E10 is issued. What to do?
There is no water in the machine or the pressure switch sensor is damaged. First add water to the heating system.
The gas boiler turns off with the display of error E03. Cleaning and blowing helps for a short time. What can be done?
This situation indicates a lack of traction, and the combustion products removal system should be checked. Presumably the membrane is stuck. In other cases, it is necessary to contact a specialist for a thorough examination of the gas boiler with further inspection.
There is a Baltur boiler. Error E06 began to appear. The unit itself functions, the temperature of the liquid is set by the manual switch. During its installation, it seems that they overheated, because they turned on the automatic temperature mode. The outdoor air temperature sensor was not installed. For what reason did this happen?
Most likely, the DHW temperature sensor is faulty. Sometimes the electronic board is damaged.
The unit works for approximately a few minutes, then the burner turns off, and error E03 occurs. It flashes for no more than a minute, the burner starts working again, and the device works acceptable for another 5-6 minutes, and so on constantly. This code, judging by the manual, means that the draft sensor has worked, although the chimney channel is not clogged, the flue gases are well removed. Can anyone explain what is wrong?
In your case, the probable causes that affect the lack of traction are: problems with the traction sensor. Lack of contact between the control board and the thrust sensor. Condensation in the pipes, as well as incorrect connection of the pipes to the pressure switch. The fan is damaged. It doesn’t seem to be getting the required RPM.