Biasi Combi Boiler Error Codes

Biasi Combi Boiler Error Codes Check out the table below to find your Biasi error code and see what the fault code on your Biasi boiler relates to. Biasi fault codes are generally the same across all their boilers, which makes it easier to identify the issue with your boiler. If you can’t find your fault code in the list below then we have listed every single Biasi boiler manual below that, the answers you seek shall be there!

Biasi Boiler Error Code Solutions

Fault CodeFault ImageBoiler Fault
ER 01 + ResetN/ALack of burner ignition on safety lockout
ER 02 + ResetN/ASafety thermostat intervention lockout
ER 03 + ResetN/AGeneral lockout
ER 04 +Faulty primary circuit (no water or absence of flow)
ER 05 +Faulty fan control system
ER 06 +Faulty Central Heating temp. probe NTC
ER 07 +Faulty Domestic Hot Water (DHW) temp. probe NTC
ER 08 +Faulty external temp. probe NTC
ER 09 +Faulty flue temp. probe NTC
ER 10 + resetN/AFlue probe intervention lockout
N/AFlame detection error (An flashing + number error flashing)
ER 12+Faulty central heating temperature probe NTC
ER 13 +DT Delivery return >40k
ER + 14 + ResetN/AFaulty pump or primary temperature above 105°C
ER + 14 + ResetN/AFaulty pump or primary temperature above 105°C
ER + 14 +Absence of flow from temperature gradient (>2K/s)
ER + 19 +Domestic hot water inlet probe failure (if sent)
ER + 25 + ResetN/AFlame detection fault
ER + 69N/AWiring fault lockout
LiN/APrimary circuit temp. limit during domestic hot water operation
N/ABoiler Stand-By, hyphens are turned on in sequence to simulate running/antifreeze protection activated)
N/ABoiler Stand-By, hyphens are turned on in sequence to simulate running/antifreeze protection activated)
N/AFilling request: The boiler works regularly and the display shows all the icons, but the signal FL is flashing every 1 sec.
30cN/ABoiler waiting for heat request
N/ABoiler in summer mode (d.h.w.). The primary circuit temperature is displayed.
N/ABoiler in winter mode (c.h.+ d.h.w.) The primary circuit temperature is displayed.
N/ABoiler on demand for d.h.w. power. The d.h.w. temperature is displayed. / Boiler on demand for c.h. power.
N/ABurner ignition (spark)
N/AFlame present (Burner on)
N/APre-heating function 3 starts DHW comfort. This information is not displayed. It will be possible to check its state in the section “INFO” value “cF” (the signal “cF” is alternated to the CH temperature value until the end of this function). You can enter the function by pushing buttons 12 and 13 together. The function is confirmed showing ON or OFF alternating for 5 sec. This function is always active at every hour (it’s not possible to set the time slots unless a remote control is connected).
N/APre-heating function 3 starts DHW comfort. This information is not displayed. It will be possible to check its state in the section “INFO” value “cF” (the signal “cF” is alternated to the CH temperature value until the end of this function). You can enter the function by pushing buttons 12 and 13 together. The function is confirmed showing ON or OFF alternating for 5 sec. This function is always active at every hour (it’s not possible to set the time slots unless a remote control is connected).
N/ABoiler in anti-freeze phase (bP flashing + temperature flashing)
N/ABoiler in antifrost phase (AF flashing + temperature flashing)
N/ASet c.h. (all other symbols are disabled)
N/ARemote control connected – 1 flash every 4 seconds
N/ASet d.h.w. (all other symbols are disabled)
N/APump activated for the post-circulation phase (Po flashing + temperature flashing)
N/ADelayed burner ignition for setting the system (uu flashing + temperature flashing)
N/AMaintenance required The wrench symbol is flashing (without showing any error)
LPN/ABoiler in chimney sweep in function. The activation of the chimney sweep occurs configuring the “parameter P09=01” and is visualized: LP= minimum dhw hP= minimum heating cP= maximum heating dP= maximum dhw. The transition occurs with keys 16 (increase) and 15 (decrease) dhw temperature. The writing on the display alternates.
N/ABoiler in chimney sweep function. The activation of the chimney sweep occurs configuring the “parameter P09=01” and is visualized: LP= minimum dhw hP= minimum heating cP= maximum heating dP= maximum dhw. The transition occurs with keys 16 (increase) and 15 (decrease) dhw temperature. The writing on the display alternates.