Navien Combi Boiler Error Codes

Navien Combi Boiler Error Codes Check out the table below to find your Navien error code and see what the fault code on your Navien boiler relates to. Navien fault codes are generally the same across all their boilers, which makes it easier to identify the issue with your boiler.

Navien Boiler Error Code Solutions

Boiler SystemError / Fault CodeFault Description
Combi and System003Ignition failure – manual reset needed
Combi and System004False flame error – the boiler will auto-reset
Combi and System012Flame loss – reset the boiler
Combi and System016Heat exchanger overheated – try manually resetting the boiler
Combi and System030Abnormal exhaust temperature – try manually resetting the boiler
Combi and System046Abnormal operation: Heat exchanger overheating – the boiler should auto-reset
Combi and System047Abnormal operation: Exhaust thermostat error – a manual reset is needed if it the boiler doesn’t auto-reset
Combi and System060Abnormal operation: Dual venturi limit switch – boiler will auto-reset
Combi and System109Abnormal operation: Fan error – the boiler needs resetting
Combi and System110Exhaust blockage (condensate blockage) – reset the boiler
Combi and System127Abnormal operation: Air pressure switch (APS) issue – reset the boiler
Combi and System205Heating supply thermistor open or short circuit – boiler should auto-reset
Combi and System218Alarm error: Heating return thermistor open or short circuit
Combi and System302Low water pressure – boiler should auto-reset
Combi and System352High water pressure – boiler should auto-reset
Combi and System353Abnormal operation: Water pressure sensor error – boiler should auto-reset
System407Abnormal operation: Hot water outlet thermistor – alarm error
System421Abnormal operation: Cold water inlet thermistor Auto reset should automatically occur
Combi and System480Abnormal operation: External domestic hot water (DHW) tank outlet thermistor – alarm error
Combi and System515Abnormal operation: Relay feedback (PCB) – the boiler needs to be reset
Combi and System517Abnormal operation: Dual in-line package (DIP) switch setting (PCB) – boiler needs to be reset
Combi and System594Abnormal operation: EEPROM (PCB) – contact an engineer
Combi and System615Abnormal operation: Input and memory (MCU) – try resetting the boiler
Combi and System740Abnormal operation: Outdoor temperature sensor – boiler should automatically reset
Combi and System782Abnormal operation: Main panel communication – boiler should auto-reset