Protherm Gas Boiler Error Codes

Protherm Gas Boiler Error Codes Combi fault codes with information on the brands and models you can find some. Compare the manufacturer compiled information for this information in your user’s manual with the boiler.Last updated information can be accessed from the boiler manufacturer’s web address.

Protherm Gas Boiler Error Code Solutions

Error code F28

There is no ignition of the gas boiler Protherm Cheetah. There is no gas flow to the gas burner device. The shut-off valve in the inlet gas pipeline is closed. Open shut-off valve. Purge the air from the pipeline when performing the initial start-up of the machine. Measure the pressure of the gas supplied to the gas fittings. Recommended pressure settings are given in the instruction manual. In turn, it is recommended to debug the gas pressure on the jet (minimum / maximum).

Gas valve failure. The gas valve must be changed if its breakdowns are fixed. Incorrect operation of the flame control electrode or its defect. Check and correct the distance between the flame control electrode and the burner assembly. If a fair amount of dust is noticed on the ionization electrode, clean it. Malfunction of parts of the gas unit, including a short circuit or a break in the contacts on the gas valve coils. If such malfunctions are present, install a new gas valve. Sticking of the gas valve stem. The valve has a fitting on the front. Insert the silicone tube into it and release the excess pressure. Ignition power is limited. Use the service menu of the unit and adjust the desired power. The control board has malfunctioned or is damaged.

If the ignition unit failed to work, the boiler must be restarted. If error F28 reappears, change or repair the automation board. Then you need to check the grounding. The presence of a charge on the lining is not allowed. Turning off the unit occasionally happens due to an abundant amount of moisture. ionization electrode, the burner assembly and the furnace must be thoroughly cleaned of condensate. Flame control electrode defective. There is no flame on the burner, although it is fixed by an electronic board. There was damage in the contacts or a short circuit in the wires from the ignition electrode to the control board. Diagnose electrical connections and correct problems.

Error code F22

Lack of pressure in the system. The Proterm Cheetah boiler generates an error code F22 when there is little liquid in the heating line. Damage to the contacts from the pressure switch to the control module. Malfunction of the minimum pressure sensor. First check what values ​​are shown on the pressure gauge. If the pressure is low, pour the coolant into the heating system. For this procedure, the unit is equipped with a make-up tap. If error F22 continues, it is recommended to inspect the system in search of a possible leak. Leaks can appear in the hydraulic pump, the valve of the protection group, at the primary heat exchanger, and in addition, in deformed gaskets and seals.

Error code F20 (F24)

Overheating of the Protherm Gepard boiler. The emergency thermostat began to heat up to a temperature of 103 degrees. Error code F20 will not be logged when there is currently no ignition message. When the temperature in the heating circuit rises, the burner goes out, although the heat exchanger does not stop heating. When the temperature of the protective sensor for overheating rises to 103 C, bypassing 15 seconds. the device will stop functioning due to the operation of the electronics module. When the thermostat recognizes temperatures above 100 C in heating mode, the electronics waits for a probable temperature drop for an average of 25 seconds.

If the decrease in the temperature of the heating NTC sensors and the thermostat does not occur within the specified period of time, the gas boiler displays the error code F20. Blocking at the stage of ignition of the burner assembly. If the temperature of the overheat protection sensor in the stage when the flame is formed is more than 103 C, the control automatics notifies of the malfunction only after a 10 second wait. Activation of the heating water temperature sensor or overheating protection thermostat, which block the device. If the water temperature rises to the level of 103 C, the emergency overheating thermostat starts. After the unit has cooled down, restart it using the reset key. Damaged or malfunctioning overheating relay.

It needs to be replaced. Water circulation in the heating circuit is difficult. If, when checking the pressure of an unheated heating system, it is found that it has dropped, fill the device with liquid. There is excess air in the heating pipeline. Use an automatic vent to remove air from the piping system. Cessation of circulation. To ensure that the water circulates without interference, fully open the stopcocks on the pipelines. The smoke exhaust thermostat is overheating. Restart the machine when the thermostat sensor has cooled down.

Error F75

The circulation pump began to work with violations. Reduced pump speed. There is no stable voltage in the electrical network. In case of systematic difficulties with electricity, it is required to connect the device to the network through a stabilizer. The water circulation pump motor is broken or there is a short circuit in the stator winding. Weak pressure, however, the operation of the circulation pump is in normal mode. Presumably, the blades were damaged, which is why it is recommended to change the hydraulic pump.

The coolant is supplied to the hydraulic pump continuously, but it does not spin. The hydraulic pump will need to be checked for possible jamming of the rotor shaft. The plug is unscrewed, then we scroll the rotor shaft of the electric motor with our hands. There is no communication between the electronics module and the circulation pump, which is a malfunction in the control module. If this fault occurs again after the unit has been rebooted, change the automation module.

Error code F25

Lack of traction. The Protherm Cheetah boiler functions correctly and stably if there is good draft in the chimney. Electronics monitors that combustion products do not enter the living quarters, and at the time of fixing problems, the draft sensor blocks the device with error code F25. Possible reasons why traction is weak or absent altogether. The smoke exhaust duct is too small in diameter or there were shortcomings during its installation. The presence of blockages or ice on the inner walls.

The permissible length of the flue duct has been exceeded. Read the relevant requirements and standards in the installation instructions. Pressure switch damaged. You need to test it and change it if necessary. The connections from the pressure switch to the control unit are broken. Test electrical connections and troubleshoot. Moisture is present, and in addition, the tubes are incorrectly connected to the pressure switch. Remove condensate and correctly connect the pipes to the draft sensor. The fan is defective. The fan blades are clogged. The fan does not rotate well because there is not enough lubricant on its shaft. Damage to the contacts from the control unit to the fan.

Error code F01 (F10)

The temperature sensor on the heating line is damaged. The Protherm Gepard gas boiler reports an error F01 (F10) when the set temperature rises, or when the heating circuit temperature sensor fails. The temperature sensor circuit for heating is broken. If the contact from the thermal sensor to the electronic board is damaged, this malfunction occurs. The return to the correct operation of the unit after an accident will begin after 10 seconds if the malfunction was spontaneous.

If during the test period it turns out that there is no condensation on the sensor connector and the contacts of the control board, replace the temperature sensor. The sensor circuit connections are shorted, or the fluid temperature is too high. Measure the temperature resistance first. If the resistance does not match the required standards, the temperature sensor must be replaced.

Error code F12 (F13) The

DHW temperature sensor is broken. The automatic system of the boiler Proterm Cheetah signals an error F12 (F13) when there is a malfunction of the DHW temperature sensor or the temperature recommended for stable operation has increased significantly. If damage to the DHW temperature sensor is revealed, it must be replaced. Damage to the contacts from the electronic module to the hot water temperature sensor. Diagnose the contacts of the electrical circuit and find the fault. If the electrical connections between the temperature sensor and the automation module are normal, the sensor itself is operational, but the error F12 (F13) is displayed, in this case it can be argued that the control board is damaged.

Error F29

Failure of the gas burner functions during ignition. Error F29 reports that ignition does not take place due to the attenuation of the gas burner flame. Inspect the electrical connections from the ignition unit to the ionization electrode or from the gas valve to the electronic module. Repair circuit connections if problems are found. In addition, insufficient draft can cause malfunctions that are associated with flameout. Check the chimney for blockages.

Boiler errors Proterm Leopard

Error code F1

Ignition of the Protherm Leopard gas boiler is not performed. There is no inflow of gas fuel to the burner. The shut-off valve in the inlet line is closed. You will need to open the shut-off valve. Purge air from the piping line when starting the unit for the first time. Measure the pressure of the gas supplied to the gas unit. The required pressure values ​​are written in the user manual. In addition, you should adjust the gas pressure on the jet (maximum / minimum). The gas valve is defective. The gas valve is recommended to be changed if its damage is determined.

Unsatisfactory functioning of the ignition electrode or its defect. Check and adjust the distance between the ionization electrode and the burner. If there is a fair amount of dust on the ignition electrode, clean it. Breakage of gas valve elements, in particular, breakage or short circuit of contacts on the gas valve coils. If such violations are found, replace the gas valve. Stuck gas valve. A fitting is located on the outside of the valve. Attach a rubber tube to it and remove excess pressure. Ignition power is insufficient. Enter the user menu of the unit and adjust the required power. The control module functions failed or it is damaged. If the ignition mechanism could not work, you need to restart the boiler. If the F1 error reappears, repair or replace the printed circuit board. Finally, the grounding is checked. Do not charge on the skin.

The shutdown of the unit in some cases is due to a significant amount of condensate. ionization electrode, the combustion chamber and the gas burner block will need to be cleaned thoroughly from condensate. The flame control electrode is defective. There is no flame on the gas burner, but it is detected by the control module. There was a violation in the connections or a short circuit in the wiring from the control board to the ionization electrode. Diagnose wiring and fix problems.

Error code F0

Unsatisfactory pressure in the system. The Proterm Leopard boiler notifies of an F0 error if the liquid level in the heating system is low. The connections from the electronic board to the pressure sensor are broken. Failure of the pressure sensor. First of all, find out what values ​​\u200b\u200bare shown on the pressure gauge. At reduced pressure, add coolant to the heating system. To fill the liquid, the unit is equipped with a make-up valve. If the F0 error starts to appear again, it is recommended to inspect the system in search of a potential leak. Leaks can be in the circulation pump, the emergency relief valve, at the main heat exchanger, and in addition, in worn gaskets and seals.

Error code F3

The Protherm Leopard boiler overheats. The protective thermostat has heated up to a temperature of 103C. An F3 error will not be logged if there is currently no fire message. When the temperature in the main circuit becomes high, the burner unit goes out, but the heat exchanger does not stop heating. When the temperature of the protective sensor rises to overheat to 103 degrees, after 20 seconds the operation of the device will stop due to the operation of the control automation.

When the temperature sensor fixes a temperature above 100 degrees in the heating cycle, the automation waits for a possible decrease in temperature for about 25 seconds. If the decrease in the temperature of the heating NTC sensors and the thermostat does not occur within the specified time, the boiler issues an error code F3. Shutdown when igniting the burner. If the temperature of the emergency overheating thermostat in the cycle when the flame appears is above 103 C, the electronics will report a failure at 10 second intervals.

Operation of the overheating safety thermostat or the temperature sensor for heating, stopping the unit. When the water temperature reaches the level of 103 C, the overheating temperature sensor turns on. After the instrument has cooled down, reset it by pressing the reset button. Damaged or incorrectly triggered overheating temperature sensor. It will need to be changed. The water circulation in the heating circuit is limited. If, during the period of measuring the pressure of a cooled heating system, it is determined that it is too low, pour liquid into the unit. There is excess air in the heating pipeline. Use an automatic vent to remove air from pipes. There is no circulation process. To ensure that the liquid circulates smoothly, fully open the shut-off valves on the water lines. The circulation pump began to function with violations. Reduce pump speed.

There is no stable voltage in the power supply network. In case of regular complications with electricity, it is recommended to connect the boiler to the electrical network using a stabilizer. The circulation pump motor is broken or there is a short circuit on the stator winding. Weak pressure, however, the operation of the circulation pump is normal. The impeller is probably damaged, so you need to replace the pump. Water is supplied to the hydraulic pump intensively, but it does not spin. It is recommended to check the pump for possible misalignment of the rotor shaft.

The plug is removed, then we turn the rotor shaft of the electric motor by hand. There is no contact between the control module and the circulation pump, which is a malfunction of the control module. If this problem persists after the reset of the device, change the electronics module. The flue gas thermostat has started to overheat. Restart the unit when the thermostat has cooled down. The flue gas thermostat has started to overheat. Restart the unit when the thermostat has cooled down. The flue gas thermostat has started to overheat. Restart the unit when the thermostat has cooled down.

Error code F6

There is no traction. The Protherm Leopard boiler works stably and safely when there is good draft in the flue duct. Automation ensures that combustion products do not enter the living quarters, and in the event of a malfunction, the traction sensor-relay blocks the unit with error F6. Possible reasons why there is no traction at all or it turns out to be bad. The smoke outlet channel has a small hole diameter or inaccuracies during its installation. The presence of blockages or ice on the inner walls.

The permissible length of the flue duct has been exceeded. Read the relevant codes and regulations which are described in the installation manual. Traction air relay damaged. It should be checked and changed if necessary. The connections from the pressure switch to the control module are damaged. Diagnose circuit connections and correct problems. The formation of moisture, and in addition, incorrectly attached to the sensor tube. Remove moisture and properly connect the tubes to the air pressure switch. Fan damage. Clogged fan blades. Too low fan speed due to insufficient lubrication on the drive shaft. The connections from the control board to the fan are broken.

Error code F2

The temperature sensor in the heating circuit is defective. The Proterm Leopard boiler displays an F2 error when the operating temperature increases, or when the temperature sensor of the heating line is damaged. The electrical circuit of the heating water temperature sensor is broken. If the communication from the temperature sensor to the electronic board is damaged, this fault occurs.

Restoring the functions of the device after an accident will begin after 10 seconds, if the problem was unreasonable. If during the diagnostic process it turns out that there is no moisture on the temperature sensor connector and the contacts of the control board, change the temperature sensor. The temperature sensor electrical circuit contacts are shorted or the water temperature is too high. Check the resistance at the temperature sensor first. If the resistance does not meet the required standards, the sensor must be replaced. If a new temperature sensor is connected, but the F2 error occurs again, replace or repair the automation unit.

Error code F4

The hot water temperature sensor has failed. The automation of the Protherm boiler Leopard reports an F4 error if the DHW temperature sensor breaks or the temperature recommended for stable operation has risen significantly. If a defect in the hot water temperature sensor is found, it is supposed to be replaced. Damage to the contacts from the electronics module to the hot water temperature sensor. Diagnose the electrical contacts and find the fault. If the electrical contacts between the control module and the sensor are not broken, the sensor itself is serviceable, but the F4 error is determined one way or another, in which case it can be argued that the electronic unit is malfunctioning.

Code F7

Communication error. This malfunction indicates damage in the connections between the display and the board. Restart boiler. Check the circuit board-to-display for an open or short. The pressure in the coolant system has dropped below the permissible minimum. Top up the system to the 1-2 bar mark.

Error F5

Gas burner failure during ignition. Error F5 notifies that ignition does not take place due to the attenuation of the burner flame. Check electrical connections from the flame electrode to the ignition unit or from the gas valve to the control unit. Repair electrical contacts if problems are identified. In addition, a lack of thrust can be a source of malfunctions that cause flame separation. Inspect the chimney for contaminants.

Errors of boilers Proterm Panther

Error code F28

Protherm Panther gas boiler ignition failure. There is no inflow of the gas mixture to the gas burner block. The shut-off valve on the gas supply pipe is closed. You will need to open the shut-off valve. Purge the air from the pipeline if the unit is being started up for the first time. Check the pressure of the gas supplied to the gas fittings. The required pressure parameters are prescribed in the user manual. In addition, it is recommended to adjust the gas pressure on the nozzle (highest / lowest). Failure of the gas valve. The gas valve must be changed if its defects are found. Unstable operation of the ionization electrode or its failure. Check and correct the gap between the ignition electrode and the gas burner unit.

If you find quite a lot of soot on the ignition electrode, clean it. Breakage of gas equipment components, including short circuit or broken contacts on the gas valve coil. If such violations are found, install a new gas valve. Stuck gas valve. The fitting is located in front of the valve. Attach the silicone tube to it and remove excess pressure. Ignition power is unsatisfactory. Use the service menu of the boiler and adjust the desired power.

The control board has malfunctioned or is defective. If the ignition mechanism failed to work, you will need to restart the boiler. If error F28 occurs again, change or repair the control board. Then the grounding is checked. The presence of voltage on the case is not allowed. Turning off the device occasionally occurs due to a significant amount of moisture. The ionization electrode, the burner device and the combustion chamber must be thoroughly cleaned of moisture. Flame control electrode defective. There is no flame on the burner block, but it is fixed by the automation module. There was damage to the contacts or a short circuit in the electrical cable from the ignition electrode to the control board. Diagnose the electrical circuit and fix problems.

Error code F22

Reduced pressure in the system. The Proterm Panther gas boiler notifies of error ER002 when the coolant level is lowered in the heating line. Breakage of connections from the control board to the minimum pressure sensor. Pressure sensor failure. First, check what values ​​the pressure gauge shows. If there is a lack of pressure, fill the heating system with coolant. A make-up valve is installed on the device to fill the water. When error F22 reappears, the system should be checked for potential leakage. Leaks can occur in the hydraulic pump, emergency relief valve, primary heat exchanger, and deformed seals and gaskets.

Error F20 (F24)

The Protherm Panther boiler goes into overheating. The heating temperature of the protection thermostat is 103 degrees. Error F20 will not be registered if the ignition signal is not currently given. When the temperature in the heating circuit rises, the gas burner goes out, but the heating of the heat exchanger is not interrupted. At the moment the temperature of the emergency overheating sensor rises to 103C, after 15 seconds the operation of the unit will stop due to the operation of the automation module.

If the thermostat detects a temperature of more than 100 degrees in the heating cycle, the automation waits for a potential decrease in temperature for an average of 30 seconds. If, however, the temperature of the sensor does not decrease according to the heating temperature and the protective thermostat within the specified time, the boiler issues the error code F20. Blockage during ignition of the gas burner. If the temperature of the safety thermostat in the stage when the flame is formed is more than 103 degrees, the automation system transmits a malfunction signal only after a 10-second wait.

Activation of an emergency overheating thermostat or a heating water temperature sensor that turns off the unit. When the water temperature rises to 103 degrees, the overheat sensor will work. After the instrument has cooled down, reset it using the reset key. The temperature sensor for overheating does not work correctly or is broken. Will need to change it. The circulation of the heating medium in the heating circuit is too weak. If, during the measurement period, the pressure of the unheated heating circuit is found to have decreased, top up the unit with water. There is excess air in the heating pipeline. It is recommended to use an automatic vent to remove air from the pipelines. There is no circulation process. To ensure that the coolant can circulate freely, fully open the shut-off valves on the pipelines.

Code F75

The circulation pump is unstable. The rotation of the pump is unsatisfactory. There is no required voltage in the mains. In case of repeated power outages, the boiler should be connected to the electrical network through a stabilizer. The electric motor of the circulation water pump is damaged or the stator winding is shorted. Insufficient pressure, although the functioning of the circulation water pump is satisfactory. The vanes may be broken, so you need to install a new pump. Water enters the pump without delay, but it does not rotate. The hydraulic pump will need to be tested for possible misalignment of the rotor shaft.

The plug is removed, then the rotor shaft of the engine is scrolled by hand. There is no communication between the automation module and the pump, which is due to the failure of the control module. If after restarting the boiler the current problem occurs again, change the automation module. The exhaust gas thermostat is overheating. Restart the device when the thermostat has cooled down.

Error F25

Lack of traction. The Proterm Panther boiler works correctly and stably when there is good draft in the chimney. The automation system monitors that flue gases do not enter the room, and at the time of the occurrence of malfunctions, the draft sensor-relay stops the operation of the unit with error code F25. The main reasons why traction becomes bad or it is completely absent. The smoke exhaust channel is very small in diameter or miscalculations during its installation. The presence of blockages or ice on the inner walls. The maximum length of the flue duct has been exceeded. Refer to the installation manual for the relevant codes and requirements.

Traction relay defective. It should be checked and replaced if necessary. The connections from the control board to the traction air relay are broken. Check electrical connections and troubleshoot. Condensation is present, and in addition, the tubes are incorrectly connected to the pressure switch. Remove moisture and properly connect the tubes to the draft sensor. Fan failure. The fan impeller is clogged. Reduced fan speed due to insufficient lubrication of the drive shaft. Damage to the contacts from the fan to the control board.

Error F01 (F10)

The temperature sensor on the heating line is inoperable. The Protherm Panther boiler notifies of an error during an increase in the set temperature, or due to a breakdown in the temperature sensor of the heating system. The heating temperature sensor circuit is damaged. If the contact from the temperature sensor to the electronics module is broken, this fault occurs. The restoration of the correct operation of the unit after a failure will begin in a few seconds if the failure was spontaneous. If during the test it is determined that there is no condensation on the contacts of the electronic module and the temperature sensor connector, install a new temperature sensor.

The electrical circuit connections of the temperature sensor are closed, or the coolant temperature is above normal. Check the resistance at the temperature sensor first. If it does not meet the standards, the temperature sensor must be changed. If you have installed a working temperature sensor, nevertheless, error F01 (F10) is issued again, repair or change the printed circuit board.

Error F12 (F13)

Defective hot water temperature sensor. The automation system of the Protherm Panther boiler displays the error code F12 (F13) when there is a malfunction of the hot water temperature sensor or the temperature recommended for stable operation has risen significantly. If damage to the hot water temperature sensor is revealed, it must be replaced. Breakage of contacts between the hot water temperature sensor and the control board. Check electrical contacts and troubleshoot. If the contacts between the control board and the temperature sensor are not damaged, the temperature sensor itself is operational, however, the F12 (F13) error is determined one way or another, therefore, it can be argued that the automation module is malfunctioning.

Error F29

Failure of the functions of the burner during ignition. Error F29 reports that ignition is not performed due to the attenuation of the gas burner flame. Diagnose the contacts of the electrical circuit from the ignition unit to the flame electrode or from the gas valve to the control module. Repair electrical contacts if damage is found. In addition, unsatisfactory draft can cause malfunctions that are associated with flameout. Check the flue duct for dirt.

Boiler errors Proterm Lynx

Error code F1 (F28)

Ignition of the boiler Proterm Lynx is not performed. There is no gas supply to the burner. The distribution valve on the inlet line is closed. Open the distribution valve. Purge the air from the pipe line if the instrument is switched on for the first time. Measure the pressure of the gas entering the gas valve. The required pressure indicators are set out in the user manual. In addition, you will need to adjust the pressure of the gas mixture on the jet (maximum / minimum). The gas valve is broken. The gas valve must be replaced if its defects are fixed. Unsatisfactory operation of the ionization electrode or its damage. Check and correct the interval between the flame control electrode and the gas burner unit.

If contamination is found on the electrode, clean it. Malfunctions of parts of the gas unit, for example, open or short circuit of the contacts of the gas valve coil. If the above problems are present, replace the gas valve. The gas valve could be stuck. A fitting is located on the outside of the valve. Put a rubber hose over it and remove excess pressure. The ignition power of the gas boiler Proterm Lynx is limited. Use the service menu of the boiler and adjust the required power. The functions of the electronics module are broken or it is faulty. If the ignition unit does not work, the unit must be restarted. If error F1 (F28) reappears, change or repair the automation board.

Finally, check the grounding. The presence of voltage on the skin is not allowed. Switching off the boiler occasionally may be due to a significant amount of condensate. The ignition electrode, combustion chamber and burner must be thoroughly cleaned of moisture. The ionization electrode is broken. There is no flame on the burner, but it is detected by the control module. Broken contacts or cable short circuit from the electrode to the electronics unit. Diagnose the electrical circuit and fix problems.

Error F22 (F83)

Decreased pressure in the system. The Protherm gas boiler Lynx gives an error F22 (F83) when there is not enough coolant in the heating circuit. The contacts from the control board to the minimum pressure sensor are broken. Failure of the differential pressure switch. Find out in advance what readings are displayed on the pressure gauge. At low pressure, feed the heating system with coolant. To fill the coolant, the unit is equipped with a make-up valve. If error F22 (F83) repeats, you need to check the system to identify a possible leak. Leaks may be present in the hydraulic pump, emergency relief valve, at the main heat exchanger, and in addition, in damaged seals and gaskets.

Error F3 (F20)

Boiler overheating Proterm Lynx. The protection thermostat has reached a temperature of 103C. F3 Fault (F20) will not be latched when there is no ignition request at the moment. When the temperature in the heating line rises, the burner goes out, but the heat exchanger does not stop heating. When the temperature of the protective overheating thermostat rises to 103 degrees, bypassing 20 seconds. the operation of the device will be suspended due to the operation of the automation system. When the temperature sensor detects more than 100 C in the heating cycle, the automation system waits for a potential decrease in temperature for approximately 30 seconds.

If the decrease in the temperature of the heating NTC sensor and the safety thermostat does not occur during this period, the Proterm Lynx boiler displays the error code F3 (F20). Failure to work when igniting the burner. If the temperature of the emergency overheating thermostat in the cycle when the flame occurs is above 103C, the electronics will notify the failure only after 10 seconds of waiting.

Operation of the heating temperature sensor or overheating thermostat blocking the device. If the coolant temperature reaches 103 degrees, the emergency overheating thermostat turns on. After the device has cooled down, restart it using the reset button. Overheating relay broken or not working properly. It needs to be changed. The water circulation in the heating circuit is too weak. If, during the process of checking the pressure of a cooled heating circuit, it becomes clear that it has decreased, pour liquid into the unit. There is air in the heating pipe. Use an automatic vent to remove air from the piping system. No circulation. For normal circulation of the liquid, fully open the shut-off valves on the water main.

Error F75

The circulation pump is not working properly. Reduced pump speed. There is no required voltage in the mains. In case of repeated complications with electricity, it is necessary to connect the device to the network using a stabilizer. The circulation pump motor has broken or the stator winding has shorted. Low pressure, but the circulation pump is operating normally.

Presumably, the blades broke, so it is necessary to change the hydraulic pump. The coolant is supplied to the pump intensively, although it does not spin. The pump must be inspected for possible misalignment of the rotor shaft. The plug is unscrewed, then the rotor shaft of the electric motor is manually scrolled. There is no pulse from the electronics board to the circulation pump, which is a malfunction in the control board. If, after restarting the unit, this malfunction occurs again, the automation module is changed. The flue gas thermostat is overheated. Restart the boiler when the thermostat cools down.

Error code F6 (F25)

There is no traction. The Protherm Lynx gas boiler operates stably and safely if there is good draft in the chimney. Electronics controls that flue gases do not penetrate into the living quarters, and at the time of the occurrence of malfunctions, the traction pneumatic relay stops the unit with error F6 (F25). Here are some reasons why traction becomes weak or it is completely absent. The chimney duct is very narrowed or there are shortcomings during its installation.

There is dirt or frost on the walls from the inside. Exceeding the permissible length of the smoke exhaust duct. Refer to the installation instructions for the proper rules and regulations. Traction sensor damaged. It is recommended to test it and change if necessary. The connections from the control board to the traction air relay are broken. Diagnose the electrical circuit and troubleshoot. The formation of condensate, and at the same time, the pipes are incorrectly connected to the pneumatic relay.

Remove condensate and properly connect the pipes to the draft sensor. The fan is not working properly. Clogged fan blades. Too low fan speed due to insufficient lubrication on the drive shaft. Violation of contacts from the electronic unit to the fan. Too low fan speed due to insufficient lubrication on the drive shaft. Violation of contacts from the electronic unit to the fan. Too low fan speed due to insufficient lubrication on the drive shaft. Violation of contacts from the electronic unit to the fan.

Error code F2

The temperature sensor in the heating system is damaged. The Lynx boiler displays an F2 error during an increase in the set temperature, or as a result of a failure of the heating line temperature sensor. The temperature sensor circuit for heating is damaged. If communication between the control board and the temperature sensor is broken, this problem occurs. Return to the correct operation of the device after a failure will occur after 10 seconds, if the failure was spontaneous.

If during the diagnostic process it turns out that there is no moisture on the contacts of the electronic board and the sensor connector, install a new sensor. The sensor circuit connections are shorted, or the fluid temperature is too high. Measure the resistance on the sensor first. If it does not meet the required standards, the sensor must be replaced.

Error code F4

Defective hot water temperature sensor. The electronics of the Protherm Lynx boiler notifies the F4 error if a malfunction of the DHW temperature sensor occurs or the temperature necessary for stable operation has noticeably increased. If a breakdown of the DHW temperature sensor is revealed, it will need to be changed. Rupture of contacts between the hot water temperature sensor and the control module. Check the contacts of the electrical circuit and look for defects. If the contacts between the temperature sensor and the board do not have breaks, the temperature sensor itself is working, but the F4 error is generated, therefore, it can be argued that the control module is broken.

Error code F29

Failure of the burner during ignition. Error F29 reports that ignition is not performed due to the burner flame breaking off. Inspect the electrical contacts from the ignition unit to the flame electrode or from the gas valve to the control module. Restore the electrical contacts if any problems are found. In addition, insufficient draft can cause malfunctions that lead to flameout. Check the chimney for blockages.