CODE: Er 01
PROBLEM: The tumble dryer door has been opened while the machine is running
FIX: Close the door. Do not open the door until the program is completed

CODE: Er 02
PROBLEM: Overflow switch error
FIX: Check for water leakage. Check the overflow switch operation. Check wiring to overflow switch

CODE: Er 03
PROBLEM: Not used, idle
FIX: Not used

CODE: Er 04
PROBLEM: Door temperature sensor (NTC) has exceeded 60˚C
FIX: The door sensor has exceeded a safe temperature, the compressor will stop for five minutes. Restart program after cool down. The front thermistor is defective or the control is recieving a false reading. Check wiring to thermistor. Replace the thermistor

CODE: Er 05
PROBLEM: Start/Pause/Cancel buttom pressed during program
FIX: Restart program

CODE: Er 06
PROBLEM: Compressor temperature sensor (NTC) has exceeded safe limits
FIX: The compressor sensor has exceeded a safe temperature, the compressor will stop for four minutes. Restart program after cool down. The compressor thermistor is defective or the control is recieving a false reading. Check wiring to thermistor. Replace the thermistor

CODE: Er 07
PROBLEM: Not used, idle
FIX: Not used

CODE: Er 08
PROBLEM: Drying program has exceeded the maximm permitted time
FIX: For cotton and synthetic programs the limit is 300 minutes . Restart the cycle after cool down and test again

CODE: Er 09
PROBLEM: Mains supply voltage too low, less than 165 Volts
FIX: Corrrect mains supply voltage

CODE: Er 10
PROBLEM: Mains supply voltage too high, greater than 265 Volts
FIX: Corrrect mains supply voltage

CODE: Er 11
PROBLEM: Compressor temperature sensor (NTC) has exceeded maximum permitted operation limits
FIX: The compressor NTC can only operate with up to 40 instances of being over the maximum permitted temperature in a single program, if this limit is exceeded then this error code will be displayed anda cool down phase initiated.
Restart program after cool down. The compressor thermistor is defective or the control is recieving a false reading. Check wiring to thermistor. Replace the thermistor

CODE: Er 12
PROBLEM: Rotary error
FIX: Check operation rotary control

CODE: Er 13
PROBLEM: Not used, idle
FIX: Not used

CODE: Er 14
PROBLEM: Humidity Sensor has exceeded the maximm permitted time
FIX: For cotton and synthetic programs the limit is 300 minutes
Restart the cycle after cool down and test again

CODE: Er 15
PROBLEM: Drum idle at the start of sensor drying programs
FIX: Check operation of the drum. Check motor operation. Check drive belt

CODE: Er 16
PROBLEM: Door NTC or thermistor open circuit and the tumble dryer will halt
FIX: The front door thermistor is defective or the control is not in contact with it. Check wiring. Replace the thermistor

CODE: Er 17
PROBLEM: Comperssor NTC or thermistor open circuit and the tumble dryer will halt, program aborted
FIX: The compressor thermistor is defective or the control is not in contact with it. Check wiring. Replace the thermistor

CODE: Er 18
PROBLEM: Door NTC or thermistor short circuit and the tumble dryer will halt
FIX: The front door thermistor is defective or the control is not in contact with it. Check wiring. Replace the thermistor

CODE: Er 19
PROBLEM: Comperssor NTC or thermistor short circuit and the tumble dryer will halt, program aborted
FIX: The compressor thermistor is defective or the control is not in contact with it. Check wiring. Replace the thermistor

CODE: Er 20
PROBLEM: Rotary control turned while the dryer is in operation
FIX: Restart program

Modern Blomberg washer dryers make doing the laundry simple. With a large 8kg wash and 5kg dry capacity, you can empty the washing basket in one go. Motors are quiet and energy-efficient. And wash through dry programmes will wash and dry clothes in one continuous cycle.

Stylish digital displays make setting the cycles easy – even showing the remaining time for each programme. But what does it mean when the digital display shows a different code? Look at some Blomberg dyer problems and troubleshooting below…

Washer Dryer Fault Codes

Blomberg tumble dryer error codes will guide you to the possible cause of the problem – but you may have to call a trained technician to fix it for you. See a range of Blomberg dryer error codes here…

  • Er 01– this indicates that the tumble dryer door has been opened while the machine is running. If this persists you may have a problem with the door latch
  • Er 02 –an error has occurred with the overflow switch which requires the wiring to be checked on the switch itself, the operation of the switch, and any water leakage issues
  • Er 04 – the door temperature sensor has exceeded a safe temperature stopping the compressor. This may be due to a faulty thermistor, defective wiring, or problems with the control panel
  • Er 08 – the drying cycle has exceeded the maximum permitted time and points to a possible issue with the heat pump
  • Er 09 – the mains supply voltage is too low and requires a qualified engineer to investigate
  • Er 10 – the mains supply voltage is too high and needs a qualified engineer to correct it
  • Er 15 – the drum is stationary at the start of the drying programme caused by the drum or motor operation, or the drive belt
  • Er 16 – tumble dryer stopping during the cycle indicates the front door thermistor or the wiring is defective – the thermistor may need replacing

Washer Dryer Troubleshooting

A Blomberg washer dryer, not drying could be due to a faulty element or thermostat and these will need to be checked with a multimeter to obtain relevant readings. This will determine if the parts need to be repaired or replaced.

A faulty fan or motor could also be the culprit here – fluff and lint can get into the fan and prevent it from spinning. And a defective motor will obviously affect the workings of the dryer and may also need to be replaced.

The venting system should also be checked to ensure that it’s clear and there’s good airflow.

If the door won’t open on your Blomberg washer dryer this could be resulting from the inability of the washer to drain. As a safety precaution, the door will automatically lock.

Failure to start may be related to the door not closing properly. Or could be due to a fault with the sensor or pressure pad that detects when the door is closed. A faulty seal will also affect door closure.

A qualified engineer will be able to test for all these faults as well as ensuring the power supply, plugs, sockets, and fuses are all in order.

Automatic switch over problems can happen when the programme has been set to switch over to drying after washing but then fails to do so. If water has stayed in the drum after the wash cycle this could be the cause. You may need help and advice in emptying any remaining water from the drum for this feature to be restored.

Leave a Comment