Hoover Dryer Error Codes

Hoover Dryer Error Codes Whether there is a fault code displayed on your Hoover tumble dryer, you hear strange noises or you see a LED light flashing, it is the way to tell if there is an issue with your dryer. Yet, it is not always so easy to put your finger on which component is the faulty one. But don’t panic just yet! To understand what your appliance is trying to tell you, use our guide below on common Hoover tumble dryer error codes. Unfortunately except cleaning your tumble dryer’s filters all other fault codes will require some expertise to locate and fix the issue, so unless you are experienced handyman its advisable that you contact professional Hoover tumble dryer repair.

Hoover Dryer Error Code Solutions

ERROR CODEMOST PROBABLE REASON FOR THE ERROR CODE
E03Tank is full of water and has to be emptied
E05Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or wiring
E07Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is occluded because of fluff  presence, the correct ventilation is not allowed. Clean the filter
E08 Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is clean, check the  wiring
E10 Missing communication between “Cuore” Electric Module and Display Electric Module and/or Wiring
E11In the rear part of condenser the temperature is too high. Check that all ventilation ducts are clean, check that ventilation system is working well. Check the condenser, the moto  the fan could be broke/blocked.
E12Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air trap is clean
E13 Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC probe and/or wiring
E14 Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or wiring
E15Main board not programmed. Program the main board
E19It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off and switch on)
E21   Heater control relay on the “cuore” electric module is not working. High temperature has been reached – Thermo Fuse worked. Check the Thermo Fuse, and the wiring. Check both the ventilation circuit and ventilation ducts are clean and duct is not obstructed. Replace the “cuore” electric module only in the case that the heater command relay is faulty
E22

Compressor control relay on the “cuore” electric module is not working. Check the compressor and compressor wiring/connections. Replace the “cuore” electric module only in the case that the compressor command relay is faulty.

 