Liebherr Freezer Error Codes When your Liebherr Freezer refrigerator is out of service, it doesn’t mean you have to call for a master. You can repair on your own using the troubleshooting tables below: they contain error codes and descriptions of malfunctions. You will be able to identify the possible cause of failure and define the measures to be taken to fix it up.
Liebherr BioFresh Freezer error codes
Problem | Possible Cause | Correction |
---|---|---|
An LED at the lower rear of the appliance (near the compressor) flashes regularly every 5 seconds. | There is a fault. | ► Contact the customer service department |
The temperature display indicates: F0 to F9. | There is a fault. | ► Contact the customer service department |
DEMO lights up in the temperature display. | The demo mode is activated. | ► Contact the customer service department |
Liebherr GFT50S2HC Freezer error codes
Error codes displayed | Cause and further action |
---|---|
E0 or E1 | Sensor error. > Contact the customer service department. |
EE or EF | Error in the electronic control system. > Contact the customer service department. |
L0 | Temperature in the interior is too low. > Contact the customer service department. |
HI | Temperature in the interior is too high (warm). > First make sure that the door is closed properly. If the HI display does not disappear after approx half an hour, contact the customer service department. |
dor | The appliance door has been left open for more than 1 minute. > Close the door. |
HF or HA | There has been a power outage (HF) of some length or the interior was too warm or too cold (HA). |